Evidence map›Paper›PMID 42563628›Full record

ArticleJMIR nursing2026

Theoretical Exploration of Error Thresholds for Clinical AI Decision Support in Nursing: Exploratory Simulation Study Grounded in Human-AI Reliance Data.

Hiroyuki Tajima

Abstract read
In one paragraph

Article in JMIR nursing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Hiroyuki TajimaFaculty of Nursing, Shumei University, 1-1 Daigaku-cho, Yachiyo, Chiba, 276-0003, Japan, 81 47-488-2111.ORCID http://orcid.org/0000-0003-3817-4455

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Clinical AI decision support is being introduced into nursing practice; however, existing large language models (LLMs) demonstrate only moderate accuracy on complex clinical tasks, raising questions about the level of accuracy required for safe clinical use across varying levels of clinician experience and task complexity. Objective: The aim of the study is to develop an empirically calibrated simulation model of human-AI reliance and error in nursing decision-making and estimate the AI accuracy required to achieve specified error rate targets. Methods: A linear reliance model with coefficients for AI accuracy (A), clinician experience (E), and task complexity (C) was calibrated using weighted least squares against 9 empirical data points from 3 independent randomized experiments on AI-assisted decision-making (N=3502). Predicted error was computed as reliance×(1-A) across a 27-cell factorial design. Study-level bootstrap (2000 iterations) quantified calibration uncertainty. To contextualize the simulation's operating range, the accuracy of contemporary general-purpose LLMs on complex clinical tasks was drawn from published benchmarks. Results: Calibration placed βA at 0.201 (bootstrap 95% CI 0.023-0.234; P(βA>0)>.99). For the novice×high-complexity combination, the minimum AI accuracy values required to achieve error rates <10% and<20% were 0.89 and 0.78, respectively (bootstrap 95% CIs 0.88-0.90 and 0.75-0.79). At the moderate accuracy levels currently reported for general-purpose LLMs on complex clinical tasks (approximately 0.5-0.7), the model predicts error rates of roughly 26% to 41% in this high-risk condition. Conclusions: In this model, keeping predicted error rates below a stringent target (<10%) for high-complexity nursing decision support by novice clinicians requires AI accuracy of at least approximately 0.89, a level that current general-purpose LLMs may not reliably reach on complex clinical tasks. Because the model is calibrated on nonnursing reliance data, these thresholds are illustrative model outputs, not nursing-derived empirical standards. The Athreshold framework provides a decision-theoretic tool for evaluating the minimum AI accuracy requirement by user-and-task profile. Behavioral validation in nursing contexts remains an essential next step. Because the framework is independent of any specific model, it remains applicable as AI systems improve.

Indexed as

Artificial IntelligenceDecision Support Systems, ClinicalComputer SimulationHumansLarge Language Modelsautomation biasclinical decision supporterror thresholdlarge language modelsMonte Carlo simulationnursing informatics

Identifiers

PMID42563628
PMCPMC13448014

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.