Evidence map›Paper›PMID 42563473›Full record

ArticleMedical physics2026

Theoretical assessment of DECT noise on physical and biological dose accuracy in carbon-ion radiation therapy.

Weiguang Li, Yan Li, Shutong Yu, Xueying Yang, Chao Yang, Cheng Chang, Mingqing Wang, Chong Xu, Kai-Wen Li, Li-Sheng Geng and 1 more

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Weiguang LiSchool of Physics, Beihang University, Beijing, China.
Yan LiSchool of Physics, Beihang University, Beijing, China.
Shutong YuDepartment of Technology, CAS Ion Medical Technology Co., Ltd, Beijing, China.
Xueying YangHangzhou International Innovation Institute, Beihang University, Hangzhou, Zhejiang, China.
Chao YangDepartment of Technology, CAS Ion Medical Technology Co., Ltd, Beijing, China.
Cheng ChangDepartment of Technology, CAS Ion Medical Technology Co., Ltd, Beijing, China.
Mingqing WangDepartment of Radiation Oncology, Cancer Center, Peking University Third Hospital, Beijing, China.
Chong XuZhejiang Cancer Hospital, Department of Radiation Physics, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China.
Kai-Wen LiDepartment of Technology, CAS Ion Medical Technology Co., Ltd, Beijing, China.
Li-Sheng GengSchool of Physics, Beihang University, Beijing, China.
Yibao ZhangKey Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing, China.

Funding

Beijing Natural Science Foundation Z230003Clinical Research Fund For Distinguished Young Scholars of Peking University Cancer Hospital QNJJ2023018Fundamental Research Funds for the Central Universities BMU2025PYJH041Heavy Ion Research Facility in Lanzhou 2025-HIRFL-ZD-003013National Natural Science Foundation of China 12275012National Natural Science Foundation of China 12411530076/cost-share with UK Royal Society International Exchanges Award IEC-NSFC-233138National Natural Science Foundation of China 12475309Science Foundation of Peking University Cancer Hospital BJCH2025GG05
6 · The paper itself

Abstract

backgroundAccurate characterization of tissue parameters is essential for precise dose calculation in Carbon Ion Radiation Therapy (CIRT). Recent advances in Dual-Energy CT (DECT) have improved the estimation of tissue parameters, yet DECT-based methods are susceptible to image noise. The influence on physical and biological dose accuracy has not been thoroughly investigated, undermining the evidence-based clinical application and protocol optimization.

objectiveTo systematically examine how image noise in DECT influences the estimated tissue parameters and its consequent impact on the accuracy of physical and biological dose distributions in CIRT. MATERIALS AND

methodsFour DECT-based elemental decomposition methods were evaluated. A machine-learning (ML) approach was compared with three parameterization (PA) methods, that is, the Hünemohr model using input parameters (

resultsAcross the investigated noise levels, the ML approach consistently outperformed the three PA methods. Compared with PA-based methods, the ML approach reduced the average water-equivalent range deviations by 0.4 mm-1.4 mm and improved gamma passing rates by 0.8%-3.9% (physical dose) and 6.4%-24.1% (biological dose) under the 1 mm/1% criteria.

conclusionThe ML method provides superior robustness and accuracy in physical and biological dose calculation based on DECT of various noise levels. The LEM demonstrated superior noise robustness compared to the LQM and the MKM.

Indexed as

Heavy Ion RadiotherapyRadiation DosageSignal-To-Noise RatioTomography, X-Ray ComputedHumansPhantoms, ImagingRadiotherapy Dosagebiological dosecarbon ion radiation therapydose calculationdual energy CTmaterial decomposition

Identifiers

PMID42563473
PMCPMC13448101

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.