ArticleJournal of applied clinical medical physics2026
Characterizing electronic noise interference from the external laser positioning system on a radiation therapy MRI simulation scanner.
Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMagnetic resonance imaging (MRI) for radiation therapy treatment planning is currently being used in many anatomical sites to better visualize soft tissue landmarks, a technique known as an MRI simulation. A core component of modern MRI simulation configurations are the use of external laser positioning systems (ELPS) to help set up the patient. Though necessary for accurate and reproducible patient setup, the ELPS, if left on during imaging, may interfere negatively with image quality due to leaking electronic noise, of which MRI is sensitive to. PURPOSE: It is currently unknown whether this leakage of electronic noise may further affect quantitative values derived from clinically employed relaxometric, diffusion, and fat fraction sequences. Therefore, in this study, we aim to characterize the impact of MRI simulation lasers on general image quality and quantitative imaging accuracy.
methodsFirst, a cine acquisition was used to visualize the real-time changes in image signal-to-noise ratio (SNR) from when the ELPS was deactivated to activated. To validate this effect quantitatively, the SNR was measured using the American College of Radiology (ACR) recommended T1-weighted protocol in a homogeneous phantom with the integrated body, 18-channel UltraFlex small, 18-channel UltraFlex large, 32-channel spine, and 16-channel shoulder coils. Next, a geometric distortion algorithm was tested in two vendor-provided phantoms while using the integrated body coil and the ACR Large Phantom protocol was tested. Finally, a series of quantitative MRI scans were performed using a CaliberMRI Model 137 Mini Hybrid phantom to validate quantitative T1, T2, and ADC while a Calimetrix PDFF-R2* phantom was used for quantitative PDFF and R2*. All scans were performed with both the ELPS both deactivated and activated.
resultsVisible electronic noise artifacts were seen when using the integrated body coil when the ELPS was activated on the cine acquisition which led to a two-fold decrease in SNR using the ACR protocol, however geometric distortion quantification was not affected. This SNR drop was not seen when using the remaining tested coils. Degradation in image intensity uniformity, percent signal ghosting, and low contrast object detectability was seen during ACR Large Phantom testing using the 20-channel Head/Neck coil. Concordance across quantitative MRI values was similar when the ELPS was both deactivated and activated while a consistent increase in standard deviation inside the ADC vials was seen when the ELPS was activated.
conclusionsThe extra noise induced from the activation of the ELPS during imaging should be avoided due to its potential to unnecessarily increase image noise. This is particularly true when conducting mandatory quality assurance testing for image quality and geometric distortion which utilize the integrated body coil which is most susceptible to ELPS-induced noise. Clear clinical guidelines should be implemented to make this issue known to the MRI technologists, physicists, and other relevant staff using an MRI with a supplementary ELPS for patient alignment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.