Evidence map›Paper›PMID 42563010›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Isometric points in cerclage for patellar tendon repair: a 3-dimensional, weightbearing computed tomography kinematic simulation.

Christoph Zindel, Sandro Hodel, Yichao Luo, Michel Meisterhans, Sandro F Fucentese, Lazaros Vlachopoulos

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christoph ZindelDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland. christoph.zindel@balgrist.ch.ORCID https://orcid.org/0000-0002-6253-9824
Sandro HodelDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
Yichao LuoDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
Michel MeisterhansDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
Sandro F FucenteseDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
Lazaros VlachopoulosDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe gold standard for the management of ruptured patellar tendon is the surgical repair with nonabsorbable sutures and additional reinforcement e.g. cerclage wires as described by McLaughlin in 1947. Despite the early description, the exact placement of such cerclage wires remains unclear. The aim of the study was (1) to analyze how the cerclage elongates during knee flexion and (2) to define the insertion points with the most isometric behavior at the patella and tibial tuberosity (TT).

methods3D simulations of 10 healthy knees in the range from 0° to 120° of flexion using weightbearing computed tomography scans were generated. 12 insertion points were defined at the patella in equal distances along the lateral and medial border from the proximal to the distal pole. 42 insertion points were defined at the tibial tuberosity (TT) in a 3.0 × 3.0 cm large grid around its center. An automatic string simulation algorithm was used to calculate the length for all possible combinations of the cerclage from 0° to 120° flexion. The most isometric combination of insertion points was found using the isometric score.

resultsThe most isometric insertion at the TT is distally (p < 0.01) and towards the center of the TT (p < 0.01). The most isometric points at the TT is located 61 mm distal to the joint line and 5 mm from the anterior border of the TT in a true lateral view fluoroscopy. The insertion on the patella is insensible, as long as the patella is not bypassed proximally (p < 0.01).

conclusionElongation of patella tendon augmentation or cerclage can be reduced when choosing a distal and central insertion at the TT, while the insertion on the patella does not affect elongation as long as the patella is not by passed proximally. This might help to reduce excessive stress and prevent cerclage or augmentation failure.

Indexed as

Bone WiresPatellar LigamentBiomechanical PhenomenaHumansImaging, Three-DimensionalTomography, X-Ray ComputedWeight-Bearing3D preoperative planningHigh tibial osteotomyPatientspecific instrumentsPosterior slope

Identifiers

PMID42563010
PMCPMC13447453

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.