Evidence map›Paper›PMID 42560985›Full record

ArticlePloS one2026

Magnetic bead-based enhancement of qPCR detection rates in low-density Plasmodium falciparum samples: A comparative analysis of nucleic acid extraction methods.

Ruo-Qiao Wen, Wei Ning, Fang Peng, Miao-Miao Wang, Jie-Peng Huang, Bin Tian

Abstract readComparative Study
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ruo-Qiao WenThe First Clinical Medical College, Inner Mongolia Medical University, Hohhot, Inner Mongolia, China.
Wei NingClinical Laboratory Department, Changsha Municipal Center for Disease Control and Prevention, Changsha, Hunan, China.
Fang PengClinical Laboratory Department, Changsha Municipal Center for Disease Control and Prevention, Changsha, Hunan, China.
Miao-Miao WangClinical Laboratory Department, Changsha Municipal Center for Disease Control and Prevention, Changsha, Hunan, China.
Jie-Peng HuangClinical Laboratory Department, Changsha Municipal Center for Disease Control and Prevention, Changsha, Hunan, China.
Bin TianClinical Laboratory Department, Changsha Municipal Center for Disease Control and Prevention, Changsha, Hunan, China.ORCID https://orcid.org/0009-0005-2603-6305

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn post-elimination malaria settings, monitoring asymptomatic low-density infections following Artemisinin-based Combination Therapy (ACT) is critical for interrupting occult transmission and alerting to drug resistance. Real-time quantitative PCR (qPCR) is central to molecular surveillance, yet its sensitivity depends on extracted DNA quality. This study evaluated three DNA extraction methods to provide a basis for optimizing laboratory screening protocols for low-density Plasmodium falciparum (P. falciparum) infections.

methodsNucleic acids were extracted from P. falciparum-positive whole blood samples using a silica membrane spin column method (M1), a modified red blood cell lysis method (M2), and a magnetic bead-based method (M3). DNA concentration and purity (A260/A280 ratio) were measured, and integrity assessed via agarose gel electrophoresis. Template yield and amplification efficiency were compared by qPCR. Furthermore, the detection sensitivity was compared between M1 and M3 via serial dilution experiments. Clinical performance was validated using 40 microscopy-negative or low-density (<150 parasites/µL) samples collected 48 hours post-treatment.

resultsM3 yielded significantly higher DNA concentration (39.0 ± 7.57 ng/µL) than M1 (10.49 ± 2.73 ng/µL) and M2 (7.48 ± 1.76 ng/µL) (P < 0.0001). Although M3 had a slightly lower A260/A280 ratio, electrophoresis showed it better preserved high-molecular-weight DNA. qPCR confirmed that the template yield from M3 was approximately 4.0-fold and 2.8-fold higher than that from M2 and M1, respectively. Serial dilution experiments demonstrated that M3 exhibited significantly higher detection sensitivity, with a lower limit of detection (LOD) than M1. Among the 40 clinical low-density samples, the positive detection rate for M3 (77.5%, 31/40) was significantly higher than for M1 (60.0%, 24/40) (P = 0.0082), with M1 showing a missed detection rate of 22.6% (7/31).

conclusionThe magnetic bead-based method (M3) exhibits marked advantages in DNA yield, DNA integrity and downstream qPCR sensitivity, which elevates the detection rate of low-density P. falciparum and reduces missed detection risk. For post-elimination surveillance and screening of asymptomatic infections, prioritizing magnetic bead-based nucleic acid extraction can provide more reliable technical support for molecular surveillance in post‑elimination settings.

Indexed as

DNA, ProtozoanMalaria, FalciparumPlasmodium falciparumReal-Time Polymerase Chain ReactionHumansSensitivity and SpecificityDNA, Protozoan

Identifiers

PMID42560985
PMCPMC13446695

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked