Evidence map›Paper›PMID 42560085›Full record

ArticleJournal of applied clinical medical physics2026

Comparison of three commercial multi-energy CT and electron density phantoms for iodine quantification and tissue substitute characterization.

Artur Omar, Robert Vorbau, Jens Zimmerman, Gavin Poludniowski

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Artur OmarMedical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.ORCID https://orcid.org/0000-0002-2643-7994
Robert VorbauMedical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
Jens ZimmermanMedical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
Gavin PoludniowskiMedical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMulti-energy computed tomography (MECT) and electron density (ED) phantoms are designed for evaluating the performance of CT scanners. They include substitute materials representing the energy- and material-dependent CT numbers of different organs, tissues, or contrast agents. While MECT phantoms are intended for dual-energy CT (DECT) and photon-counting CT (PCCT) applications, ED phantoms are meant for the calibration of CT numbers to a metric relevant for radiation therapy treatment planning. PURPOSE: To compare three standard commercial phantoms in terms of iodine quantification for diagnostic imaging and tissue substitute characterization for radiation therapy. The phantoms investigated include the Multi-Energy CT/Advanced Electron Density Phantom (AED) by Sun Nuclear Corporation (Melbourne, FL, USA), the CIRS Model 662/062M phantom (Norfolk, VA, USA), and the newly introduced Multi-Energy QA Phantom by QRM (Möhrendorf, Germany), for which we report the first evaluation results.

methodsThe phantoms were imaged using a GE Revolution Apex DECT scanner (GE Healthcare, Waukesha, WI, USA), a Siemens SOMATOM X.ceed DECT scanner (Siemens Healthineers, Forchheim, Germany), and a Siemens NAEOTOM Alpha PCCT scanner. Iodine-in-water inserts were evaluated using virtual monochromatic images and iodine maps, whereas the tissue equivalence of four insert sets (AED, CIRS-ED, CIRS-EPTN, and QRM) was theoretically assessed. For this purpose, vendor-specified elemental compositions and physical mass densities were used to derive relative electron density (RED), effective atomic number (EAN), mean excitation energy (I-value), and mass density (MD), which were then compared with corresponding human tissues listed in ICRU Report 44. CT scans of the phantoms containing these tissue substitutes were subsequently used for CT number calibration to proton stopping power-ratio (SPR), RED, and MD.

resultsFitted slopes for reconstructed iodine concentrations were accurate to within 8% for the QRM and AED phantom inserts. For the best performing scanner (PCCT), the slope was within 3%. The CIRS iodine-in-water inserts showed substantially higher deviations of up to 22%. Linear attenuation coefficients derived from 70 keV virtual monochromatic images generally agreed with theoretically expected values to within about 10% for the QRM and AED iodine inserts (for concentrations of 1 mg/mL or higher). Regarding the QRM, AED and CIRS-EPTN tissue substitute sets: they were closely tissue-equivalent in terms of RED, EAN, I-value (and hence SPR), but not in terms of MD. The CIRS-ED inserts were not, however, closely tissue-equivalent in terms of EAN. Consequently, the QRM, AED and CIRS-EPTN substitutes satisfy the consensus guide criteria of the European proton therapy community for CT calibration, whereas the CIRS-ED set does not.

conclusionThe commercially available phantoms of Sun Nuclear (AED) and QRM are suitable for both MECT performance assessment and CT-calibration for radiation therapy. However, the batch of CIRS iodine-in-water inserts used in this study was unsuitable for MECT assessment. Also, the tissue substitute set provided with the CIRS 062M ED phantom was less tissue-equivalent than the other sets evaluated.

Indexed as

ElectronsIodinePhantoms, ImagingTomography, X-Ray ComputedCalibrationHumansImage Processing, Computer-AssistedPhotonsRadiotherapy Planning, Computer-AssistedIodineCT number calibrationiodine quantificationmulti‐energy CTstoichiometric calibrations

Identifiers

PMID42560085
PMCPMC13446149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.