ArticleActa obstetricia et gynecologica Scandinavica2026
Vacuum-assisted hemorrhage control device versus uterine balloon tamponade for refractory atonic postpartum hemorrhage in a protocol-driven care pathway-A retrospective cohort study.
Article in Acta obstetricia et gynecologica Scandinavica, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Interpreting comparative effectiveness of vacuum-assisted hemorrhage control and uterine balloon tamponade: The impact of temporal and clinical confounding.Acta obstetricia et gynecologica Scandinavica · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionGlobally, 1 in 5 maternal deaths are attributable to major postpartum hemorrhage (PPH), despite widespread uterotonic use. Intrauterine tamponade is recommended as second-line therapy for refractory atonic PPH. Uterine balloon tamponade (UBT) achieves hemostasis through intrauterine pressure. Conversely, the vacuum-assisted hemorrhage-control device (VHD) promotes uterine contraction through negative pressure. Limited data compare these modalities. We compared the clinical effectiveness of UBT and VHD in refractory atonic PPH. MATERIAL AND
methodsThis retrospective cohort study was conducted at the National University Hospital in Singapore and included all women treated for primary PPH with either the UBT or VHD between January 2020 and September 2025, during which ROTEM-guided transfusion and E-MOTIVE-aligned practices were implemented. The composite morbidity endpoint, comprising transfusion of ≥4 units of packed red blood cells (PRBC), plasma or cryoprecipitate administration, examination under anesthesia, high dependency or intensive care unit admission, or device failure was compared between groups with logistic regression adjusted for placenta previa major and cesarean delivery.
resultsFifty-three women met inclusion criteria (33 UBT, 20 VHD). The composite morbidity outcome occurred less frequently with VHD than UBT (45.0% versus 75.8%; unadjusted OR 0.26, 95% CI 0.08-0.86, p = 0.03); after adjusting for placenta previa major and cesarean delivery, this difference was no longer statistically significant (adjusted OR 0.38, 95% CI 0.10-1.41, p = 0.15). Baseline characteristics were similar except for higher rates of placenta previa (45.5% versus 5.0%) and cesarean delivery (78.8% versus 50.0%) in the UBT group. Median estimated blood loss at device insertion was comparable (1500 mL). Among secondary outcomes, VHD was associated with lower median PRBC transfusion (1 vs. 2 units, p = 0.009), fewer women receiving ≥4 PRBC units (5.0% versus 36.4%, p = 0.02), fewer plasma transfusions (5.0% versus 36.4%, p = 0.02), shorter device indwelling duration (10.1 versus 24.3 h, p < 0.001), shorter hospital stay (54 versus 72 h, p = 0.007), and fewer high-dependency admissions (45.0% versus 72.7%, p = 0.04).
conclusionsThe VHD demonstrated outcomes comparable to balloon tamponade in managing refractory atonic PPH, with lower transfusion requirements and shorter hospitalization. VHD may be a useful component of standardized PPH protocols incorporating the E-MOTIVE bundle and ROTEM-guided transfusion, warranting further evaluation in broader clinical settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.