Evidence map›Paper›PMID 42558824›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Finite element analysis of PFNA in the treatment of osteoporotic intertrochanteric A2.3 fractures of the femur.

Fan Wang, Na Liu, Ruohan Pan, Yanhui Zhang, Chengdong Chen, Chaochao Huang, Jian Wang, Haihan Song, Xingpeng Zhang, Wen Wang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fan WangShandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China.
Na LiuTianjin Walkman Biomaterial Co., Ltd., Newton Laboratory, Tianjin, China.
Ruohan PanShandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China.
Yanhui ZhangDepartment of Orthopaedics, The First Affiliated Hospital of Shandong First Medical University and Shandong Provincial Qianfoshan Hospital, Jinan, Shandong, China.
Chengdong ChenShandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China.
Chaochao HuangTianjin Walkman Biomaterial Co., Ltd., Newton Laboratory, Tianjin, China.
Jian WangDepartment of Orthopedics, Shanghai Pudong New Area People's Hospital, Shanghai, China.
Haihan SongDepartment of Orthopedics, Shanghai Pudong New Area People's Hospital, Shanghai, China.
Xingpeng ZhangDepartment of Orthopedics, Shanghai Pudong New Area People's Hospital, Shanghai, China.
Wen WangDepartment of Orthopaedics, The First Affiliated Hospital of Shandong First Medical University and Shandong Provincial Qianfoshan Hospital, Jinan, Shandong, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Poor bone quality in osteoporosis can compromise implant fixation and stability in intertrochanteric fractures. This study employed finite element analysis to evaluate the biomechanical performance of short (170 mm), medium (240 mm), and long (320 mm) proximal femoral nail antirotation (PFNA) implants in osteoporotic intertrochanteric A2.3 fractures. By modulating the elastic modulus of cancellous bone to simulate varying degrees of osteoporosis severity, we aimed to identify the optimal PFNA length for clinical practice. Methods: A three-dimensional finite-element model of an osteoporotic intertrochanteric A2.3 femoral fracture was established. The elastic modulus of cancellous bone was assigned six levels (588, 445, 260, 115, 63, and 34 MPa), representing different osteoporosis severities. PFNA implants of 170, 240, and 320 mm lengths were assembled, with the 170 mm nail further evaluated at diameters of 9.5, 10, and 11 mm. Single-leg stance loading was simulated. Von Mises peak stresses in the PFNA implant, cortical bone, and cancellous bone, along with maximum displacement, were calculated and compared. Results: The 240 mm PFNA exhibited the lowest von Mises peak stress (442.86-560.44 MPa) across all bone quality conditions. The 170 mm PFNA exceeded 1000 MPa when bone quality was ≤260 MPa, surpassing the yield strength of titanium alloy (approximately 900 MPa). The 320 mm PFNA demonstrated intermediate stress (618.60-842.16 MPa). The 240 mm PFNA consistently produced the lowest cortical stress (85.191-91.948 MPa) and similar femoral displacement to the 320 mm PFNA, while cancellous bone stress decreased progressively with deteriorating bone quality (19.68→8.35 MPa). The 170 mm PFNA showed higher cortical stress (185.25-211.7 MPa) and the greatest displacement (8.05-9.44 mm), whereas the 320 mm PFNA exhibited a sharp increase when bone quality was ≤115 MPa, reaching 472.82 MPa at 34 MPa. For the 170 mm nail, increasing diameter from 9.5 mm to 11 mm reduced peak implant stress by 25.8%-49.0%, with the 11 mm nail remaining below the yield threshold in all but the most severe osteoporotic condition. Conclusion: Within the constraints of the present finite element model, the 240 mm PFNA showed the most favorable overall comparative biomechanical performance among the tested configurations and may represent a reasonable biomechanical option for osteoporotic intertrochanteric A2.3 fractures.

Indexed as

finite element analysisintertrochanteric femoral fractureintramedullary nail lengthosteoporosisPFNA

Identifiers

PMID42558824
PMCPMC13438437

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.