Evidence map›Paper›PMID 42558200›Full record

ArticleJournal of advanced periodontology & implant dentistry2026

Radiographic evaluation of malpositioning in immediate and early dental implant placement: A cross-sectional study.

Fatima Waleed Khalid, Zeinab Kadkhoda, Amir Raee, Farzaneh Mosavat, Shima Younespour

Abstract read
In one paragraph

Article in Journal of advanced periodontology & implant dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Fatima Waleed KhalidDepartment of Periodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0009-0003-0941-4234
Zeinab KadkhodaDepartment of Periodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0002-6448-6885
Amir RaeeDepartment of Periodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0002-0620-8924
Farzaneh MosavatDepartment of Oral and Maxillofacial Radiology, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0002-6251-6753
Shima YounespourResearch Center for Caries Prevention, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0003-3885-2914

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Dental implants are commonly used to replace missing teeth. Immediate implant placement (IIP) has now become an increasingly common strategy to reduce treatment time. Dental implant malposition occurs when an implant is placed at an inappropriate dimension through the bone, which leads to a variety of aesthetic and functional complications. Therefore, this study aimed to compare immediate implant placement (IIP) and early implant placement (EIP) with respect to malposition. Methods: This cross-sectional study analyzed existing clinical records and accompanying periapical (PA) radiographs of 67 immediate implant placements (IIP) and 152 early implant placements (EIP). All the implants had originally been placed by senior periodontics residents. Postoperative PA radiographs obtained at the time of surgery were reviewed to assess implant malpositioning. Dental implant malposition was defined as mesiodistal angulation≥15° or inadequate proximity (<1.5 mm to adjacent teeth or<3 mm to adjacent implants). The associations between variables and malpositioning were assessed using both univariate and multivariable logistic regression. Results: A total of 219 implants were included from 85 individuals, comprising 31 males (36.47%) and 54 females (63.53%), with a mean age of 49.88±14.06 (range: 20‒80). Multivariable logistic regression analysis indicated that both the timing of implant placement and the implant position (maxilla vs. mandible) significantly influenced the risk of malpositioning. IIP was associated with a lower probability of malpositioning than EIP (adjusted OR=0.38; 95% CI: 0.16-0.90; Conclusion: Within the limitations of this cross-sectional study, multivariable regression analysis indicated that both the timing and position of implant placement are predictors of malpositioning. IIP demonstrated a lower risk of malpositioning compared with EIP, while maxillary placement remained a significant risk factor.

Indexed as

Anatomic landmarksDental implantsImplant malpositionRadiographyTreatment timing

Identifiers

PMID42558200
PMCPMC13437220

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.