Evidence map›Paper›PMID 42555466›Full record

ArticleJournal of orthopaedic case reports2026

Clinical Outcomes of Functional Alignment Total Knee Arthroplasty using Intraoperative Sensors: A Prospective Cohort Study.

Ankit Kumar Garg, Shobhit, Mohammed Saleh AlSaifi, Mrudul Kyada, Pritam Rahaman, Gourab Biswas

Abstract read
In one paragraph

Article in Journal of orthopaedic case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ankit Kumar GargDepartment of Orthopaedics, ITSA Hospitals, Raipur, Chhattisgarh, India.
ShobhitDepartment of Orthopaedics, Pandit Deen Dayal Upadhyaya Hospital, Moradabad, Uttar Pradesh, India.
Mohammed Saleh AlSaifiDepartment of Orthopaedics, 21 September University for Medicine and Applied Sciences, Sanaa, Yemen.
Mrudul KyadaDepartment of Orthopaedics, GMERS Medical College, Vadnagar, Gujarat, India.
Pritam RahamanDepartment of Orthopaedics, Institute of Post-Graduate Medical Education and Research and Seth Sukhlal Karnani Memorial Hospital, Kolkata, West Bengal, India.
Gourab BiswasDepartment of Orthopaedics, Max Superspeciality Hospital, New Delhi, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Even with the present developments of total knee arthroplasty (TKA), a significant percentage of patients are still not satisfied after surgery, mostly because of the presence of pain and instability associated with poor balance of soft tissues. The philosophy of functional alignment has been proposed as a patient-specific philosophy of alignment with the intention to restore native knee kinematics, and intraoperative sensor technology has offered objective, real-time measurement of loads in the mediolateral compartments. There is little evidence on the integrated clinical outcome of functional alignment TKA with intraoperative sensors. Purpose: To compare clinical, functional, and biomechanical outcomes of functional alignment TKA with sensor guidance intraoperative in patients with primary knee osteoarthritis. Materials and Methods: A prospective cohort study with 50 patients undergoing primary unilateral TKA using the principles of functional alignment and intraoperative pressure-sensing technology was used. The intraoperative medial and lateral compartment loads were measured as pre- and post-balancing. Clinical outcomes, including knee society score (KSS), Visual Analog Scale (VAS), range of motion, radiographic alignment, complication rates, and patient satisfaction, were assessed pre-operatively and at 6 months post-operatively. Statistical analysis was performed using paired t-test and descriptive statistics, with P < 0.05 considered significant. Findings: Patients had poor knee performance (KSS-knee 42.6 ± 8.9; KSS-function 39.8 ± 9.4) and a high pain level (VAS 7.6 ± 1.1) pre-operatively. Significant mediolateral load imbalance at the start of the procedure (extension: 16.8 ± 6.2 lbs; 90° flexion: 10.9 ± 5.1 lbs) was significantly decreased after sensor-guided adjustments (extension: 2.5 ± 1.6 lbs; 90° flexion: 1.9 ± 1.4 lbs). KSS-knee (86.3 ± 7.4), KSS-function (82.1 ± 8.2), and VAS pain scales (1.8 ± 0.9) recorded significant improvements (P < 0.001) at 6 months post-operatively, and range of motion (118.6 ± 9.8) was improved (P < 0.001). In 88% of patients, acceptable limb positioning within the range of 3° of the neutral position was possible. The overall patient satisfaction was 92, and the rate of complication was low, and no revision was made. Conclusion: The TKA with intraoperative sensor technology functional alignment led to effective soft-tissue positioning, strong functional outcome, great pain management, and high patient satisfaction, which appears to be a promising personalized approach for TKA.

Indexed as

Functional alignmentintraoperative sensorspatient-reported outcomessoft-tissue balancetotal knee arthroplasty

Identifiers

PMID42555466
PMCPMC13348592

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.