Evidence map›Paper›PMID 42555389›Full record

ReviewNigerian medical journal : journal of the Nigeria Medical Association

A Comparison of Non-Invasive Methods of Blood Pressure Measurement in Healthy Term Neonates.

Ijeoma GeneveveEzeasouba, Frances SamOkpokowuruk, Eno EtimNyong, KevinBassey

Abstract readReview
In one paragraph

Review in Nigerian medical journal : journal of the Nigeria Medical Association. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ijeoma GeneveveEzeasoubaDepartment of Paediatrics, University of Uyo Teaching Hospital, Uyo, Akwa Ibom State.
Frances SamOkpokowurukDepartment of Paediatrics, University of Uyo Teaching Hospital, Uyo, Akwa Ibom State.
Eno EtimNyongDepartment of Paediatrics, University of Uyo Teaching Hospital, Uyo, Akwa Ibom State.
KevinBasseyDepartment of Paediatrics, University of Uyo Teaching Hospital, Uyo, Akwa Ibom State.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Invasive Blood Pressure (BP) monitoring in neonates is fraught with many complications and is rarely practical for routine monitoring, hence the need for alternative methods of BP measurements, especially in well neonates. This study aimed to compare BP measurements in neonates using Oscillometric and Doppler Ultrasound methods. Methodology: One hundred and eighty-five neonates were consecutively recruited. Blood pressure measurements were taken at 12, 24, 36, and 48 hours of life using Doppler ultrasound with Aneroid Sphygmomanometer (DAM) (gold standard), Doppler ultrasound with Hybrid Sphygmomanometer (DHM), and oscillometric methods. Data was analysed using the IBM statistical package for the social sciences (SPSS) version 23. Comparison between the mean BP values obtained from different instrumentswas done using the paired Student t-test, and the degree of agreement between values was tested using the intra-class correlation coefficient scores. Bland-Altman analyses were also done. Results: Blood pressure increased gradually from 12 to 48 hours of life. The blood pressure values using the automated oscillometric method were significantly higher when compared to the values obtained using the gold standard (p < 0.001), and the level of absolute agreement between the two methods was poor (intra-class coefficient < 0.5). Values from the DHM were not significantly different from those from thegold standard method (p > 0.05), and the level of absolute agreement between the two methods was excellent (Intra-class correlation coefficient >0.9). Conclusion: There was poor agreement between BP values using oscillometry when compared with DAM. However, the use of DAM or DHM demonstrated no difference in BP values. Caution should be exercised when interpreting values from oscillometric BP measurements in the newborn. On the other hand, either of the Doppler ultrasound methods may be used interchangeably.

Indexed as

Blood pressureDoppler ultrasound with anaeroid sphygmomanometerDoppler ultrasound with hybrid sphygmomanometerneonatesoscillometric device

Identifiers

PMID42555389
PMCPMC13379821

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.