ReviewNigerian medical journal : journal of the Nigeria Medical Association
A Comparison of Non-Invasive Methods of Blood Pressure Measurement in Healthy Term Neonates.
Review in Nigerian medical journal : journal of the Nigeria Medical Association. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Invasive Blood Pressure (BP) monitoring in neonates is fraught with many complications and is rarely practical for routine monitoring, hence the need for alternative methods of BP measurements, especially in well neonates. This study aimed to compare BP measurements in neonates using Oscillometric and Doppler Ultrasound methods. Methodology: One hundred and eighty-five neonates were consecutively recruited. Blood pressure measurements were taken at 12, 24, 36, and 48 hours of life using Doppler ultrasound with Aneroid Sphygmomanometer (DAM) (gold standard), Doppler ultrasound with Hybrid Sphygmomanometer (DHM), and oscillometric methods. Data was analysed using the IBM statistical package for the social sciences (SPSS) version 23. Comparison between the mean BP values obtained from different instrumentswas done using the paired Student t-test, and the degree of agreement between values was tested using the intra-class correlation coefficient scores. Bland-Altman analyses were also done. Results: Blood pressure increased gradually from 12 to 48 hours of life. The blood pressure values using the automated oscillometric method were significantly higher when compared to the values obtained using the gold standard (p < 0.001), and the level of absolute agreement between the two methods was poor (intra-class coefficient < 0.5). Values from the DHM were not significantly different from those from thegold standard method (p > 0.05), and the level of absolute agreement between the two methods was excellent (Intra-class correlation coefficient >0.9). Conclusion: There was poor agreement between BP values using oscillometry when compared with DAM. However, the use of DAM or DHM demonstrated no difference in BP values. Caution should be exercised when interpreting values from oscillometric BP measurements in the newborn. On the other hand, either of the Doppler ultrasound methods may be used interchangeably.
Indexed as
Identifiers
42555389PMC13379821What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.