Evidence map›Paper›PMID 42554654›Full record

ArticleThe Review of scientific instruments2026

Precise measurement of the Kerr coefficient using phase-sensitive pump-probe hyperspectral imaging.

J K Wahlstrand, C D Cruz

Abstract read
In one paragraph

Article in The Review of scientific instruments, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

J K WahlstrandNanoscale Device Characterization Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.ORCID 0000-0003-3734-8767
C D CruzNanoscale Device Characterization Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.ORCID 0009-0008-1811-4504

Funding

Intramural NIST DOC 9999-NIST
6 · The paper itself

Abstract

Phase-sensitive pump-probe hyperspectral imaging is a precise technique for absolute two-beam measurements of the optical Kerr coefficient (n2). The irradiance profile is characterized and background effects rejected by rastering the pump beam across the probe beam to yield a complex-valued hyperspectral image of the pump-induced nonlinear response. Information about the temporal irradiance profile is carried in the spectral response. The technique is demonstrated by measuring n2 of a fused silica sample near a 1 μm wavelength and benchmarked against a measurement using Z-scan [M. Sheik-Bahae et al., IEEE J. Quantum Electron. 26, 760-769 (1990)], the most widely used single-beam technique. The two measurements are consistent when the two-beam grating effect from the Raman contribution to the nonlinearity is considered. Uncertainty contributions are described in detail, and the outlook is discussed for improvements in precision.

Identifiers

PMID42554654
PMCPMC13647178

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.