Evidence map›Paper›PMID 42550697›Full record

Trial reportThe western journal of emergency medicine2026

Patient Monitor Position and Operator Ability to Visualize a Desaturation Event During Intubation.

Eric Boccio, Rachelle Perkins, James Bonz

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in The western journal of emergency medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Eric BoccioMount Sinai Medical Center of Florida, Department of Emergency Medicine, Miami Beach, Florida.
Rachelle PerkinsIntermountain Medical Center, Department of Emergency Medicine, Murray, Utah.
James BonzYale New Haven Hospital, Department of Emergency Medicine, New Haven, Connecticut.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDuring endotracheal intubation, equipment setup typically includes the patient monitor fixed at the head of the bed behind the back of the operator. Inability to directly visualize the patient monitor may result in delayed recognition of desaturation. Our primary aim in this study was to measure the association between patient monitor position and the time to recognition of a desaturation event during endotracheal intubation.

methodsWe performed a randomized crossover trial of emergency medicine residents across two Accreditation Council for Graduate Medical Education-accredited programs. Subjects were asked to perform direct and video-assisted laryngoscopy once on a difficult airway trainer in a simulation. The sequence of laryngoscopy modality (direct vs video-assisted) and monitor position (head vs left vs right of bed) were randomized prior to each attempt. The simulated patient's peripheral capillary oxygen saturation (SpO2) was programmed to begin at 100% and decrease at a rate of 1% per second 10 seconds after the start of the subject's attempt. The primary outcome measure was time to operator recognition of hypoxia defined as the observed period during which the simulated SpO2 was < 90%. Secondary outcomes were operator failure to visualize a desaturation event. We rendered Kaplan-Meier curves illustrating the time to visualization of hypoxia and performed a Cox regression adjusting for laryngoscopy modality and total number of previous intubations performed. Using multivariable linear regression, we modeled the association between time to recognition of hypoxia in seconds and patient monitor position with similar adjustments. To assess differences in the number of observed failure events between study arms, we used chi-squared or Fisher exact tests. The threshold for statistical significance was a two-sided P < 0.05.

resultsWe observed 68 attempts by 34 subjects. Twenty-two (32.5%), 22 (32.5%), and 24 (35%) intubations were performed with the monitor positioned at the head, left, and right, respectively. The median times to recognition of hypoxia were 37 seconds [sec] (95% CI, 25-86 sec) for the head, 32 sec (95% CI, 18-50 sec) for the left, and 23 sec (95% CI, 19-34 sec) for the right groups, respectively. Cox regression demonstrated hazard ratios of 2.7 and 3.2 for the left and right groups when compared to the head group, and these findings were statistically significant (P = .04 and P = 0.03, respectively). We found no statistically significant associations between time to recognition of hypoxia and laryngoscopy modality or total number of previous intubations (P = .82 and .21, respectively). Failure rates across head, left, and right groups were similar, at 36%, 59%, and 50%, respectively (P = .30).

conclusionPositioning of the patient monitor at the head of the bed results in delayed visualization of desaturation events during simulated direct and video-assisted laryngoscopy across different levels of experience. Ideally, the patient monitor should be positioned on the side of the bed and within the operator's direct line of sight. Further research is warranted to assess how equipment setup may impact procedural performance, operator ergonomics, and patient safety.

Indexed as

Clinical CompetenceEmergency MedicineHypoxiaIntubation, IntratrachealLaryngoscopyPatient PositioningCross-Over StudiesFemaleHumansInternship and ResidencyMaleOxygen SaturationTime Factors

Identifiers

PMID42550697
PMCPMC13436668

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked