Evidence map›Paper›PMID 42550385›Full record

ArticleGeneral thoracic and cardiovascular surgery2026

Anatomical lung resection using the hinotori surgical robotic system: initial clinical experience with a standardized multiport approach.

Daisuke Hokka, Shinya Tane, Ryosuke Izawa, Hiroyuki Ogawa, Yoshitaka Kitamura, Yoshimasa Maniwa

Abstract read
PubMed Publisher
In one paragraph

Article in General thoracic and cardiovascular surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Daisuke HokkaDivision of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ward, Kobe, 650-0017, Japan. dhokka@med.kobe-u.ac.jp.ORCID http://orcid.org/0009-0002-1059-1994
Shinya TaneDivision of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ward, Kobe, 650-0017, Japan.
Ryosuke IzawaDivision of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ward, Kobe, 650-0017, Japan.
Hiroyuki OgawaDivision of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ward, Kobe, 650-0017, Japan.
Yoshitaka KitamuraDivision of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ward, Kobe, 650-0017, Japan.
Yoshimasa ManiwaDivision of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ward, Kobe, 650-0017, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe hinotori™ Surgical Robotic System, the first domestically developed robotic platform in Japan, was approved for thoracic surgery in 2024. Although initial clinical experiences have been reported in other surgical fields, clinical data regarding its application in thoracic surgery remain extremely limited. This study aimed to describe the initial perioperative outcomes and feasibility of anatomical lung resection using the hinotori™ Surgical Robotic System with a standardized multiport approach.

methodsWe retrospectively reviewed patients who underwent robotic surgery using the hinotori™ system at our institution between July 2024 and March 2026. During the study period, 106 robotic procedures were performed, including 81 anatomical lung resections. After excluding mediastinal tumor resections, combined procedures, and cases performed using the dual-port robotic approach, 60 patients who underwent anatomical lung resection using a standardized multiport robotic approach were included in the final analysis.

resultsA total of 60 patients were analyzed, including 36 lobectomies and 24 segmentectomies. No intraoperative complications or conversions to video-assisted thoracic surgery or thoracotomy occurred. Postoperative morbidity was observed in 9 patients (15.0%), including Clavien-Dindo grade ≥ III complications in 4 patients (6.7%). There was no operative mortality.

conclusionsAnatomical lung resection using the hinotori™ Surgical Robotic System with a standardized multiport approach was feasible in this initial, carefully selected cohort. Further comparative studies with larger cohorts are required to determine its relative safety and efficacy compared with established robotic platforms.

Indexed as

Hinotori surgical robotic systemLobectomyRobotic-assisted thoracic surgery (RATS)Segmentectomy

Identifiers

PMID42550385

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.