Evidence map›Paper›PMID 42548861›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Accessible 2D video-based system for gait kinematic analysis: an inter-rater reliability study.

Albert Puig-Diví, Lluís Costa-Tutusaus, Juanjo García-Gil, Francesco Sartori, Javier Picañol

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Albert Puig-DivíBlanquerna School of Health Sciences, Universitat Ramon Llull, Barcelona, Spain.
Lluís Costa-TutusausBlanquerna School of Health Sciences, Universitat Ramon Llull, Barcelona, Spain.
Juanjo García-GilBlanquerna School of Health Sciences, Universitat Ramon Llull, Barcelona, Spain.
Francesco SartoriBlanquerna School of Health Sciences, Universitat Ramon Llull, Barcelona, Spain.
Javier PicañolDepartment of Health Sciences, TecnoCampus University Center, Pompeu Fabra University, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Quantitative gait analysis supports clinical decision-making and outcome monitoring, yet its use remains largely restricted to specialized laboratories due to cost and operational complexity. Smartphone-based two-dimensional video approaches using open-source software have shown promising validity, but inter-rater reliability-particularly the influence of examiner expertise across spatiotemporal and kinematic outcomes-remains insufficiently characterized in powered samples. Methods: In this observational study, 84 healthy adults were included and recorded during level barefoot walking using a standardized smartphone setup. Four examiners (two experienced, two non-experienced) independently extracted spatiotemporal parameters and hip, knee, and ankle joint angles at different gait events using Kinovea. Inter-rater reliability was assessed with intraclass correlation coefficients (two-way mixed-effects, absolute agreement; ICC [3,1]) with 95% confidence intervals, and measurement error was quantified using the standard error of measurement (SEM) and minimal detectable change (MDC95). Agreement between expert and non-expert examiners was explored using Bland-Altman plots for representative variables. Mean values were descriptively compared with established three-dimensional reference values. Results: Global spatiotemporal descriptors demonstrated excellent reliability with minimal error and limited dependence on examiner expertise (walking speed ICC = 0.96; cadence ICC = 0.98; stride length ICC = 0.96). In contrast, temporal gait phase variables showed poor reliability overall (ICC ≈ 0.31-0.43), with higher-but still limited-agreement among experienced raters. Joint kinematics exhibited joint- and event-dependent reliability following a proximal-to-distal gradient: hip angles showed the highest consistency (ICC up to 0.88), knee angles moderate-to-good agreement (ICC ≈ 0.65-0.85), and ankle angles the greatest variability, particularly for event-dependent measures (e.g., opposite toe-off ICC = 0.45). Bland-Altman analyses revealed negligible bias for spatiotemporal outcomes but wider limits of agreement for kinematic variables. Mean values were biomechanically coherent, although systematic differences in joint angles were observed when compared with 3D reference data. Conclusion: In healthy young adults, a smartphone- and Kinovea-based workflow can provide reliable spatiotemporal gait metrics and moderate-to-good reliability for selected proximal kinematics, whereas temporal gait phase variables and distal joint angles remain less reliable and should be interpreted cautiously in longitudinal or multi-examiner contexts.

Indexed as

gait analysisinter-rater reliabilitykinovealower-limb kinematicsspatiotemporal parameterstwo-dimensional analysis

Identifiers

PMID42548861
PMCPMC13429743

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked