Evidence map›Paper›PMID 42548032›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2026

Comparative Evaluation of Two Fluoroscopic Techniques in Pediatric Supracondylar Humerus Fractures: A Retrospective Study on Surgical Efficiency and Early Outcomes.

Ali Can Çiçek, Mehmet Fatih Aksay, Ümit Aygün, Orkun Halaç, Serdar Toy, Eyup Senocak

Abstract readComparative Study
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ali Can ÇiçekDepartment of Orthopedics and Traumatology, Ağrı İbrahim Çecen University, Ağrı, Turkey.ORCID 0000-0002-3260-6029
Mehmet Fatih AksayDepartment of Orthopedics and Traumatology, Ağrı İbrahim Çecen University, Ağrı, Turkey.ORCID 0000-0003-0741-2078
Ümit AygünDepartment of Orthopedics and Traumatology, Ağrı İbrahim Çecen University, Ağrı, Turkey.ORCID 0000-0001-7234-1654
Orkun HalaçDepartment of Orthopedics and Traumatology, Fethiye State Hospital, Mugla, Turkey.ORCID 0000-0002-6810-8830
Serdar ToyDepartment of Orthopedics and Traumatology, Istanbul Cam Sakura Hospital, Istanbul, Turkey.ORCID 0000-0001-8074-4672
Eyup SenocakDepartment of Orthopedics and Traumatology, Atatürk University, Erzurum, Turkey.ORCID 0000-0002-9804-9309

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Supracondylar humerus fractures are the most common elbow fractures in children and are frequently treated with closed reduction and percutaneous pinning when displaced. Because this procedure relies heavily on intraoperative fluoroscopy, surgical setup can influence operative time, radiation exposure, and workflow efficiency. However, comparative evidence on different fluoroscopic positioning strategies and antisepsis protocols remains limited. This retrospective, non-randomized study was designed to compare a conventional technique with a modified fluoroscopic approach in pediatric Gartland type II supracondylar humerus fractures. MATERIAL AND METHODS This retrospective, non-randomized comparative study included 91 children aged 1 to 13 years with Gartland type II supracondylar humerus fractures treated between 2019 and 2023. Patients were divided into 2 groups according to the surgical method: conventional method (CM, n=49) and modified method (MM, n=42). Demographic data, operative duration, fluoroscopy exposure, preparation time, radiological alignment, pin removal timing, complications, and Mayo Elbow Performance Scores were compared. RESULTS There were no significant differences in age, sex distribution, or radiographic alignment between the groups. The MM group had significantly shorter operative time, preparation time, and fluoroscopy duration. No infections or neurovascular complications were observed. Functional outcomes and fracture union were similar in both groups. CONCLUSIONS The modified technique appears to be a safe and efficient alternative to the conventional method, providing shorter operative and fluoroscopy times while maintaining comparable early clinical and radiological outcomes.

Indexed as

Fracture Fixation, InternalHumeral FracturesAdolescentChildChild, PreschoolFemaleFluoroscopyHumansHumeral Fractures, DistalInfantMaleOperative TimeRetrospective StudiesTreatment Outcome

Identifiers

PMID42548032
PMCPMC13452256

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.