ArticleJournal of applied clinical medical physics2026

Image-based evaluation of a commercial AI synthetic CT generator for brain and prostate MR-only radiotherapy.

Morgan Aire, Carson Matthews, Joshua Jones, David Duong, Christopher Schneider, Sotirios Stathakis, Olivia Shay, Krystal Kirby

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Morgan AireDepartment of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA.
Carson MatthewsDepartment of Radiation Oncology, Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana, USA.
Joshua JonesDepartment of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA.
David DuongDepartment of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA.
Christopher SchneiderDepartment of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA.
Sotirios StathakisDepartment of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA.
Olivia ShayDepartment of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA.
Krystal KirbyDepartment of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA.

Funding

Dr. Charles M. Smith Research Endowment Fund and the Kenneth R. Hogstrom Superior Graduate Student Scholarship in Medical Physics
6 · The paper itself

Abstract

backgroundSynthetic CTs (sCT) were developed to provide electron density information for MR-only treatment planning. Some AI-based sCT generators have received FDA-clearance and better capture tissue heterogeneity through voxel-wise mappings to improve image guidance and dose calculation. PURPOSE: To quantitatively characterize the image quality and geometric surrogate agreement of an FDA 510(k) cleared AI-based synthetic CT generator (TheraPanacea) for brain and prostate MR-only radiotherapy, using per-structure volumetric analysis, Hounsfield unit (HU) assessment, and multi-metric geometric evaluation.

methodsPaired CT/MR datasets from 20 brain and 20 prostate patients were retrospectively analyzed. sCTs were generated from T1w (brain) and T2w (pelvis) MR images acquired on the same day with identical immobilization. Auto-contours from TheraPanacea and MIM Contour ProtégéAI were compared against MIM Contour ProtégéAI contours on the reference CT. Bone was segmented via a fixed-threshold method. Evaluation metrics included contour volumes, cross-contour HU comparisons, centroid offsets, overlap and surface-based similarity metrics, and manual bony landmark measurements.

resultsSoft-tissue mean HU differences were <50 HU across both cohorts. Central ROIs showed <20 HU deviations, apart from heterogeneous bone and air-filled regions. Bony structures exhibited HU range compression in the sCT, where HU differences between the sCT and the reference CT differed by a maximum of 347 ± 14 HU in the femoral heads and 455 ± 50 HU in the sacrum. Global histograms confirmed HU range compression. Centroids shifted < 2 mm for all contours (brain A-P predominant, pelvis non-systematic). Boundary metrics showed MDA < 5 mm, and bony landmarks differed < 1 mm between the reference CT and the sCT. Small structures in the brain had inconsistent auto-segmentation, displaying different volumes and low Dice/JI scores. Dental implants in the sCT produced localized MR-like susceptibility artifacts. Within manual contoured implant ROIs, the mean HU values were underestimated by ∼9,000 HU relative to CT.

conclusionTheraPanacea sCT demonstrated acceptable soft-tissue HU (± 50 HU) and geometric surrogate agreement (< 2-5 mm) relative to CT, with larger errors in cortical bone, air interfaces, and implants. Site-specific QA must verify bone HU compression, peripheral geometric agreement via landmark measures, and manually review small/high-contrast contours (optic nerves, cochleae, rectum). Institutional image and dosimetric validation, particularly with implanted devices, remains essential prior to clinical deployment.

Indexed as

Artificial IntelligenceBrain NeoplasmsImage Processing, Computer-AssistedMagnetic Resonance ImagingProstatic NeoplasmsRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansMaleOrgans at RiskRadiotherapy DosageRadiotherapy, Intensity-ModulatedRetrospective StudiesAdaptive radiotherapyartificial intelligencebrainimage‐based evaluationmage-guided radiotherapyMR‐onlyprostatesynthetic CT

Identifiers

PMID42547906
PMCPMC13433487

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.