ArticleMagnetic resonance in medicine2026

Optical Detuning Strategies for Shielded Loop Resonators.

Jakob Gerlach, Reza Aghabagheri, Zining Liu, Shuai Liu, Morteza Teymoori, Çağlar Ataman, Michael Bock, Ali Caglar Özen

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jakob GerlachDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0009-0004-2305-0745
Reza AghabagheriDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0003-2786-6595
Zining LiuDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - University of Freiburg, Freiburg, Germany.
Shuai LiuDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0009-0004-0326-210X
Morteza TeymooriMicrosystems for Biomedical Imaging Group, Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany.
Çağlar AtamanMicrosystems for Biomedical Imaging Group, Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany.
Michael BockDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0001-9720-3506
Ali Caglar ÖzenDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0003-3536-0826

Funding

Deutsche Forschungsgemeinschaft 532643102
6 · The paper itself

Abstract

purposeTo compare detuning performance and evaluate power requirements of optical detuning methods and to demonstrate feasibility of an optically-detuned 4-channel receive array.

methodsFour optical detuning methods were compared in simulations, bench tests, and phantom measurements at 3T against conventional galvanic detuning. Passive detuning was also tested as an additional wireless detuning option. Optical power requirements for the detuning networks were investigated, and a flexible optically-detuned 4-channel shielded loop resonator (SLR) array was constructed and tested in vivo.

resultsA photodiode-PIN diode combination exhibited the highest unloaded Q (68.6) and Q ratio (1.9), with detuning performance and signal-to-noise ratio comparable to that of galvanic detuning at an optical power of 10 mW. Using this detuning strategy, in vivo images of the knee and brain were successfully acquired with a 4-channel flexible array.

conclusionOptical detuning is a practical alternative to conventional galvanic detuning in flexible SLR arrays. With developments in optical signal and power transmission, optimizing optical detuning while meeting manageable power requirements is an important step toward fully optical receive coil arrays. This study provides a reference point for the total optical power required for active detuning in such optical coil systems.

Indexed as

Image EnhancementMagnetic Resonance ImagingOptical DevicesTransducersBrainEquipment DesignEquipment Failure AnalysisHumansPhantoms, ImagingReproducibility of ResultsSensitivity and SpecificitySignal-To-Noise Ratioflexible receive arraylight coilsoptical detuningphotodiodeshielded loop resonator