ArticleJapanese journal of radiology2026
Diagnostic performance with sensitivity/specificity optimized computer-aided detection to detect common abnormalities in chest radiography.
Article in Japanese journal of radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo evaluate how two fixed computer-aided detection (CAD) operating modes-sensitivity-optimized (SE-CAD) and specificity-optimized (SP-CAD)-affect radiologists' diagnostic performance in chest radiography (CXR). Previous studies have focused on the performance of standalone CAD at different threshold settings. However, in clinical practice, CAD is commonly used as a decision-support tool for radiologists. This study aimed to evaluate the impact of different CAD threshold settings on radiologists' diagnostic performance. MATERIALS AND
methodsThis retrospective single-center diagnostic accuracy study evaluated posteroanterior or anteroposterior CXRs acquired between 2013 and 2023, interpreted with and without AI assistance, using CT as the reference standard. Six radiologists (three residents / three board-certified) read all cases four times over two sessions: first without CAD, then with either SE_CAD or SP_CAD, and after 1-month washout period, second session using the alternative CAD.
results375 patients (mean age, 65 ± 15 years; 170 women) were included. The dataset comprised 139 cases with pulmonary opacities (nodules / masses / consolidations), 119 with pleural effusion, 29 with pneumothorax, and 161 normal cases, including overlaps. SP_CAD-assisted readings showed higher specificity than SE_CAD-assisted for pulmonary opacities (p < 0.001). Sensitivity did not differ significantly between SE_CAD and SP_CAD assistance. For pulmonary opacities, CAD-assisted reading showed higher sensitivity (both CAD: p < 0.001) but lower specificity (SE_CAD: p = 0.006; SP_CAD: p = 0.03) than unassisted reading. For pleural effusion, CAD-assisted improved sensitivity (SE_CAD: p < 0.001; SP_CAD: p = 0.02) and specificity (both CAD: p < 0.001) than unassisted reading. For pneumothorax, SE_CAD assistance did not significantly affect sensitivity but decreased specificity, whereas SP_CAD assistance improved sensitivity without significantly affecting specificity.
conclusionThe specificity-prioritized CAD showed higher specificity than the sensitivity-prioritized CAD, without a significant reduction in sensitivity. These findings suggest that different CAD operating points can influence radiologists' diagnostic performance. We compared radiologist performance using sensitivity-optimized and specificity-optimized computer-aided detection (CAD). Different predefined CAD operating points influenced radiologist performance, resulting in differences in specificity for nodules/masses/consolidations. Our results show that different preset decision thresholds within the same AI model can influence diagnostic performance in AI-assisted radiograph interpretation.
Indexed as
Identifiers
42545563What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.