Evidence map›Paper›PMID 42543854›Full record

ArticleRapid communications in mass spectrometry : RCM2026

Multiparameter Simulation for the Optimization of Ion Transmission Efficiency Through Mass Spectrometry Inlet Capillary.

Di Wang, Chenlu Wang, Junhui Li, Jiancheng Yu, Keqi Tang

Abstract read
In one paragraph

Article in Rapid communications in mass spectrometry : RCM, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Di WangInstitute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, China.
Chenlu WangInstitute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, China.
Junhui LiInstitute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, China.ORCID https://orcid.org/0000-0001-5470-225X
Jiancheng YuInstitute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, China.
Keqi TangInstitute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, China.ORCID https://orcid.org/0009-0007-3863-653X

Funding

Hangzhou Science and Technology Development Project 20231203A18K.C. Wong Magna Fund in Ningbo University xkzwl1507Key Research and Development Program of Zhejiang Province 2024C03101Key Research and Development Program of Zhejiang Province 2024C03266Key Research and Development Program of Zhejiang Province 2025C01200(SD2)National Key Research and Development Program 2023YFC3304203Ningbo Science and Technology Project 2022Z241Ningbo Science and Technology Project 2023S151Ningbo Science and Technology Project 2023Z132Ningbo Science and Technology Project 2023Z168Ningbo Science and Technology Project 2024S047Ningbo Science and Technology Project 2024Z230Yangtze River Delta Science and Technology Innovation Community Joint Research Project 2023CSJGG1800
6 · The paper itself

Abstract

rationaleAccording to the mass spectrometry (MS) design principles, the ions generated in an atmospheric pressure ion source must pass through a narrow-bore capillary in order to maintain the needed system vacuum pressure. The ion transmission efficiency through the inlet capillary is one of the key factors directly influencing the analytical performance of MS. Its design and operating parameters, including inner diameter, length, temperature, and those related to the ion source operation, can alter ion diffusion losses, gas flow dynamics, and space-charge effects both around and inside the inlet capillary, thereby influencing ion sampling efficiency and transmission efficiency to the mass analyzer.

methodsA comprehensive simulation of ion transmission efficiency through an MS inlet capillary has been performed in this study by adjusting the important design and operating parameters.

resultsThe simulation results show that the ion transmission efficiency through the inlet capillary is positively correlated with the inner diameter of the capillary and negatively correlated with the length of the capillary. Specifically, under the conditions of a capillary diameter of 0.8 mm and a temperature of 573.15 K, the ion transmission efficiency through a 10-cm-long capillary can reach 90%. The efficiency decreases with a reduction in the inner diameter or an increase in the length. When the temperature exceeds 573.15 K, the flow field inside the capillary transits from laminar to turbulent flow, leading to a sharp decline in ion transmission efficiency. For every 100-K increase in temperature beyond this point, the ion transmission efficiency decreases by 10%-20%.

conclusionsThe main results from this study have provided crucial design guidelines, emphasizing the use of larger diameters, moderate lengths, and strict temperature control below the turbulent transition threshold to maximize ion transmission and overall instrument sensitivity for MS instruments.

Indexed as

inlet capillaryion transmission efficiencylaminar flowmass spectrometryturbulent flow

Identifiers

PMID42543854
PMCPMC13430134

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.