Evidence map›Paper›PMID 42542577›Full record

ArticlePractical laboratory medicine2026

Application of blood rheology to develop hemolysis-free serum extraction sampling method for small-volume blood.

Hideaki Isago, Baasanjav Uranbileg, Keisuke Murayama, Yuki Nakano, Yukio Kume, Yoshihiro Minagawa, Masaomi Nangaku, Hiroyuki Noji, Makoto Kurano

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hideaki IsagoDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Baasanjav UranbilegDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Keisuke MurayamaDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Yuki NakanoDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Yukio KumeDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.
Yoshihiro MinagawaDepartment of Applied Chemistry, The University of Tokyo, Tokyo, Japan.
Masaomi NangakuDepartment of Nephrology and Endocrinology, The University of Tokyo Hospital, Tokyo, Japan.
Hiroyuki NojiDepartment of Applied Chemistry, The University of Tokyo, Tokyo, Japan.
Makoto KuranoDepartment of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The growing demand for point-of-care testing (POCT) has increased interest in at-home blood testing. However, practical methods for obtaining serum from small-volume blood samples remain limited. This study investigated the effects of dilution buffers and additives on RBC aggregation and clot-formation behavior in diluted blood to develop a novel serum extraction method. Methods: Residual blood samples obtained from outpatients were used to evaluate RBC aggregation and clot-formation behavior with various dilution buffers and additives, including polyethylene glycol (PEG). Based on effective combinations, a filtration-based method for serum extraction from small-volume blood samples was developed and evaluated. Results: Dilution with saline or phosphate-buffered saline resulted in large clots and numerous floating red blood cells (RBCs). In contrast, the high-molecular-weight PEG reduced clot size and markedly decreased the number of floating RBCs. Hypertonic dilution buffers also reduced floating RBCs without disrupting clot formation. By combining PEG with hypertonic buffers, serum was successfully extracted by manual filtration without hemolysis. The extracted serum enabled C-reactive protein measurement that strongly correlated with measurements obtained from conventional serum samples. Conclusions: A simple and rapid method for hemolysis-free serum extraction from small-volume blood samples was developed using PEG and hypertonic buffers. This approach may facilitate the development of POCT applications requiring reliable serum collection from limited blood volumes.

Indexed as

Blood samplingC-reactive proteinPoint-of-care testingSerum extraction

Identifiers

PMID42542577
PMCPMC13427585

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.