Evidence map›Paper›PMID 42542451›Full record

ArticleScientific reports2026

Feasibility of energy expenditure estimation during outdoor walking using multimodal in-ear sensors: a preliminary validation study against indirect calorimetry.

David Camargo, Incinur Zellhuber, Michael Weber, Martin Schönfelder

Abstract readValidation Study
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

David CamargoDepartment of Health and Sport Sciences, Exercise Biology, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany. david.camargo@tum.de.
Incinur ZellhuberCosinuss GmbH, Munich, Germany.
Michael WeberCosinuss GmbH, Munich, Germany.
Martin SchönfelderDepartment of Health and Sport Sciences, Exercise Biology, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A growing number of portable devices has become available for daily physical activity and energy expenditure (EE) monitoring. Although several studies have examined EE estimation using heart rate (HR) and accelerometry (ACC), no study to date has explored EE prediction based on HR and ACC data measured simultaneously in the ear canal by a single commercial wearable device. Therefore, the aim of this study was to assess the feasibility of estimating EE using the cosinuss[Formula: see text] in-ear sensors [Formula: see text]One and [Formula: see text]Two. Twenty-four healthy adults (12 female, 12 male, age 26.91 ± 2.91 years, body mass 65.43 ± 8.01 kg) completed two test sessions: a laboratory treadmill test (Modified Bruce Protocol) and an outdoor walking test consisting of three phases (uphill at comfortable pace, downhill at comfortable pace, and uphill as fast as possible). EE was measured by the portable indirect calorimetry device MetaMax 3B (criterion measure), while HR and ACC were recorded continuously by the in-ear sensors [Formula: see text]One and [Formula: see text]Two. Linear mixed-effects models were developed from laboratory data and applied to outdoor walking data from the same participants (participant-calibrated prediction). Prediction accuracy was assessed using root mean square error (RMSE), mean absolute percentage error (MAPE), and Bland-Altman analysis. Both in-ear sensors showed preliminary potential for EE prediction during outdoor walking. The integration of HR, ACC, and biological sex produced the best-fitting calibration models, with marginal [Formula: see text] values of 0.79 and 0.80 for [Formula: see text]One and [Formula: see text]Two respectively. In the outdoor walking test, no significant systematic bias was detected across conditions ([Formula: see text]). However, prediction accuracy was variable across conditions and subgroups, with MAPE ranging from 22% to 37% for [Formula: see text]One and 22% to 38% for [Formula: see text]Two (following exclusion of one participant with implausible reference data in the Down phase). Pearson correlation coefficients were stronger for female participants, while male subgroup correlations were weak or negative in several conditions, limiting conclusions about individual-level prediction accuracy for this subgroup. The cosinuss[Formula: see text] in-ear sensors demonstrated preliminary feasibility for group-level EE estimation during outdoor walking, with accuracy broadly comparable to several commercial wrist-worn devices. Given the variable prediction accuracy, particularly for male participants and during downhill walking, further validation with larger and more diverse samples is needed before clinical or sports application.

Indexed as

Calorimetry, IndirectEnergy MetabolismWalkingAccelerometryAdultExercise TestFeasibility StudiesFemaleHeart RateHumansMaleWearable Electronic DevicesAccelerometryEnergy expenditureFeasibility studyHeart rateIndirect calorimetryIn-ear sensorOutdoor walkingParticipant-calibrated predictionPhysical activityWearable

Identifiers

PMID42542451
PMCPMC13428737

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.