Cochlear implant artifact analysis in cranial MRI: effects of field strength and imaging sequence.

Siqi Gao, Kaiyue Zhao, Longtao Ma, Jun Lin, Dongmei Wang, Jiayu Ni, Dian Yang, Jiaying Wang, Zili Yin, Mengxue Zhang and 3 more

Abstract read
In one paragraph

Article in Frontiers in neurology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Siqi Gao *Department of Otorhinolaryngology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
Kaiyue Zhao *Department of Radiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
Longtao MaCollege of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
Jun LinDepartment of Radiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
Dongmei WangDepartment of Radiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
Jiayu NiDepartment of Otorhinolaryngology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
Dian YangZhejiang Nurotron Biotechnology Co., Ltd., Hangzhou, Zhejiang, China.
Jiaying WangDepartment of Otorhinolaryngology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
Zili YinCentral Hospital, Jinhua, Zhejiang, China.
Mengxue ZhangHangzhou Normal University, Hangzhou, Zhejiang, China.
Yiqi MaDepartment of Otorhinolaryngology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
Hongjian HeCollege of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
Yuan LiDepartment of Otorhinolaryngology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To investigate the artifacts produced by the cochlear implant (CI) CS-30A in nonimplanted human clinical trials under different magnetic resonance (MR) field strengths and imaging sequences. Methods: The CI was placed at a standardized surface projection location on the temporal region of 12 healthy subjects. Axial cranial MR scans were performed at both 1.5 T and 3.0 T field strengths using the following sequences: T1-weighted spin-echo (SE), T2-weighted fast spin-echo (FSE), and T2*-weighted gradient-echo (GRE). The maximum dimension of CI artifacts was measured, and the artifact area was quantified using both manual measurement and a deep learning-based automatic segmentation algorithm. The impact of CI artifacts on the visibility of brain anatomy was evaluated by radiologists. Results: Under both 1.5 T and 3.0 T MR scanning, GRE sequences exhibited significantly larger artifact maximum dimension and area than SE and FSE sequences ( Conclusion: GRE sequences produced a wider range of CI artifacts than SE and FSE sequences at both 1.5 T and 3.0 T. No significant difference in artifact size was observed between the two field strengths. The artifact areas on SE sequences showed high consistency between manual measurement and the deep learning-based automatic segmentation algorithm. Therefore, SE or FSE sequences should be prioritized over GRE for CI recipients, and both 1.5 T and 3.0 T are clinically feasible.

Indexed as

artifactcochlear implantfield strengthimage qualityimaging sequencemagnetic resonance

Identifiers

PMID42539506
PMCPMC13423841

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.