Dual-Filament 3D Printing of Patient-Specific CT Phantoms with Embedded Implants and Tunable Metal-Artifact Intensity.

Pouyan Pasyar, Kai Mei, Jessica Y Im, Leonid Roshkovan, Michael Geagan, Peter B Noël

Abstract readPreprint
In one paragraph

Article in medRxiv : the preprint server for health sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pouyan PasyarDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Kai MeiDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Jessica Y ImDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Leonid RoshkovanDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Michael GeaganDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Peter B NoëlDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.

Funding

PixelPrint: a 3D printing platform for creating lifelike patient-based CT phantomsR01EB035092 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI Peter B Noel · 2024 to 2026
$1.8M
Ultra-high spatial resolution photon-counting CT with multiple focal spotsR01EB035908 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI Peter B Noel, JOSEPH Webster STAYMAN · 2025 to 2026
$1.2M
NIBIB NIH HHS R01 EB035092NIBIB NIH HHS R01 EB035908
6 · The paper itself

Abstract

Background: Metallic implants such as orthopedic screws, prostheses, and dental hardware produce beam-hardening, photon-starvation, and streak artifacts that degrade computed tomography (CT) image quality, and the metal artifact reduction (MAR) methods developed to mitigate them require objective, reproducible benchmarking. Purpose: Objective evaluation of MAR algorithms in CT is hindered by the absence of phantoms that simultaneously provide anatomically realistic backgrounds, embedded implants of known geometry, and controllable, ground-truth-referenced artifact intensity. We present a dual-filament, voxel-level three-dimensional (3D) printing method that fulfills these requirements and demonstrate its capabilities on a clinically representative cervical spine case with embedded orthopedic spinal screws. Methods: The proposed method extends the Results: The dual-filament method reproduced patient anatomy, soft-tissue contrast, and screw geometry with high fidelity. ROI HU values agreed with patient data within ±25 HU for soft tissue and trabecular bone; cortical regions were underestimated owing to the current ceiling of the calcium-doped PLA used in this study. The tunable-artifact behavior was quantified as follows: the Gumbel location parameter μ scaled monotonically from 46.7 HU (no-metal background) to 57.1 HU (50% infill) to 90.5 HU (85% infill) for the VMI 70 keV with standard filter. High-keV VMI reconstructions substantially reduced streak and beam-hardening artifacts while preserving anatomic detail. Conclusions: The proposed dual-filament, voxel-level

Indexed as

3D printing methodologydual filamentfused deposition modelingmetal artifact reductionorthopedic implantsphantom designPixelPrintspectral computed tomographyvoxel-level multi-material printing

Identifiers

PMID42539165
PMCPMC13419654

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.