ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026
EndoTac: An Endoscopic Camera-Based Tactile Sensor with High Sensitivity for Minimally Invasive Surgery.
Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Minimally invasive surgery (MIS) removes direct tactile feedback from surgical procedures, making it challenging for surgeons to manipulate delicate anatomy, such as vasculature and other soft tissue. Existing tactile tools developed for MIS in prior research are either too bulky or have limited sensing coverage, restricting their utility in practical surgical workflows. To address these challenges, we introduce EndoTac, a novel miniaturized vision-based tactile sensor designed to traverse a standard trocar while offering a large sensing area with high sensitivity. EndoTac integrates an endoscopic camera to achieve a compact and MIS-compatible form factor, and employs a convex mirror to capture the contact information across a wide sensing area, thereby maximizing effective sensing coverage. A soft membrane further enables the sensor to achieve high sensitivity by deforming under gentle interactions with soft and fragile tissue like vascular structures. Experimental results demonstrate that EndoTac achieves a low detection threshold of 20.5 mN, a high pixel-level sensitivity slope in the low-force regime, improved force resolution, and reliable estimation of vessel deformation in vascular palpation tests. Together, these results show that EndoTac provides a significant step toward restoring tactile perception in MIS, offering a practical pathway to safer and more precise surgical manipulation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.