Anatomical fit of the oneKNEE tibia design using statistical shape modeling.

Ingrid Dupraz, Yukihide Minoda, Nikolai Kornilov, Brigitte Altermann, Philipp Hauff, Arthur Bollinger, Berna Richter, Thomas M Grupp

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ingrid DuprazResearch and Development, Aesculap AG, Tuttlingen, Germany.ORCID https://orcid.org/0000-0002-2402-7780
Yukihide MinodaDepartment of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Nikolai KornilovOrthopedic Department N 17, Vreden National Medical Research Center of Traumatology and Orthopedics of the Ministry of Health of Russian Federation, Saint Petersburg, Russian Federation.
Brigitte AltermannResearch and Development, Aesculap AG, Tuttlingen, Germany.
Philipp HauffResearch and Development, Aesculap AG, Tuttlingen, Germany.
Arthur BollingerResearch and Development, Aesculap AG, Tuttlingen, Germany.
Berna RichterResearch and Development, Aesculap AG, Tuttlingen, Germany.ORCID https://orcid.org/0009-0005-4327-2166
Thomas M GruppResearch and Development, Aesculap AG, Tuttlingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

INTRODUCTION AND

aimModern tibial implants should be designed to achieve an optimal anatomical fit. The aim of this study was to evaluate how well a newly developed tibial implant design (oneKNEE® - B. Braun Aesculap, Tuttlingen, Germany) matches patient anatomy compared to three existing implant systems, using Statistical Shape Models (SSM).

methodSSMs for Caucasian and Asian populations were generated using CT scans of 120 Caucasian and 112 Asian osteoarthritic patients. Border anatomical variations were represented by individual anatomies from 14 Caucasian and 12 Asian patients. Tibial components were positioned in accordance with strict protocols established by senior knee surgeons (YM, NK). The anatomical fit was analyzed across all four implant systems in terms of antero-posterior and medio-lateral dimensions, tibial coverage and cortical bone support. Global tests for homogeneity and Dunnett's tests were performed.

resultsBony coverage for Asian and Caucasian populations ranged from 82.9% to 88.4% for long-established designs and from 85.0% to 91.2% for more recently introduced designs. Among all designs, the oneKNEE® implant demonstrated superior bony coverage and cortical support, followed by Attune® (Depuy-Synthes, Warsaw, IN, USA), Columbus® (B. Braun Aesculap), and PFC Sigma® (Depuy-Synthes). For average anatomies, oneKNEE® showed significantly better bony coverage and cortical score compared to Columbus® and PFC Sigma® (P < 0.01). In less average anatomies, oneKNEE® exhibited statistically superior bony coverage compared to PFC Sigma®, although no significant difference was observed in cortical support.

conclusionCompared with established tibial implant designs, the new design demonstrated improved virtual anatomical fit and coverage metrics based on computational modeling. These findings reflect a theoretical design‑level improvement and require biomechanical and clinical validation.

Indexed as

Knee ProsthesisModels, StatisticalProsthesis DesignTibiaAgedArthroplasty, Replacement, KneeAsian PeopleFemaleHumansMaleMiddle AgedModels, AnatomicOsteoarthritis, KneeTomography, X-Ray ComputedWhite People

Identifiers

PMID42536626
PMCPMC13426962

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.