Evidence map›Paper›PMID 42536540›Full record

ArticleMedicine2026

Biomechanical efficacy of wire fixation methods for oblique metacarpal shaft fractures.

Yung-Cheng Chiu, Tsung-Yu Ho, Chen-Wei Yeh, Ming-Tzu Tsai, Cheng-En Hsu, Jui-Ting Hsu

Abstract read
In one paragraph

Article in Medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yung-Cheng ChiuSchool of Medicine, China Medical University, Taichung, Taiwan.
Tsung-Yu HoSchool of Medicine, China Medical University, Taichung, Taiwan.
Chen-Wei YehSchool of Medicine, China Medical University, Taichung, Taiwan.
Ming-Tzu TsaiDepartment of Medical Equipment Development and Application, Hungkuang University, Taichung, Taiwan.
Cheng-En HsuDepartment of Orthopaedics, Taichung Veterans General Hospital, Taichung, Taiwan.
Jui-Ting HsuDepartment of Biomedical Engineering, China Medical University, Taichung, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFractures of the metacarpal shaft are common. In treating stable metacarpal fractures, conservative treatment with splint immobilization yields favorable outcomes. Complex and unstable fractures typically require surgical intervention. The objective of this study was to determine the fixation capabilities of multiple combinations of K-wires and cerclage wiring in treating oblique metacarpal shaft fractures.

methodsVertical oblique metacarpal fractures at the midshaft of 28 artificial metacarpal bones (Sawbones, Vashon) were induced by using an electric saw. The fractured metacarpal bones were divided into 4 fixation treatment groups: Group 1 used 2 K-wires (2K), group 2 used 1 K-wire and a cerclage wire (1K&CW), group 3 used a vertical bone wire and a cerclage wire (VBW&CW), and group 4 used a lateral bone wire and a cerclage wire (LBW&CW). To measure maximum fracture force and bone stiffness, cantilever bending tests were conducted. The fixation capabilities of the 4 groups were compared using analysis of variance and Tukey test.

resultsMaximum fracture force in the LBW&CW group (mean ± standard deviation, 113.60 ± 8.66 N) considerably exceeded that in the VBW&CW group (66.51 ± 17.27 N) and that in the 1K&CW group (65.44 ± 16.59 N). The 2K group (36.10 ± 8.32 N) exhibited the weakest maximum fracture force. The ranking of the groups from highest to lowest by average stiffness was as follows: LBW&CW group (32.34 ± 4.62 N/mm), VBW&CW group (25.47 ± 5.96 N/mm), 1K&CW group (17.70 ± 6.27 N/mm), and 2K group (15.51 ± 2.48 N/mm).

conclusionThe LBW&CW method provides superior fixation strength to that of the other 3 methods in the fixation of midshaft vertical oblique metacarpal fractures.

Indexed as

Bone WiresFracture Fixation, InternalFractures, BoneMetacarpal BonesBiomechanical PhenomenaHumansK-wire and cerclage wire fixationoblique metacarpal shaft fracture

Identifiers

PMID42536540
PMCPMC13433097

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.