ArticleJournal of applied clinical medical physics2026

Performance evaluation of a new type of commercial silicon detectors for photon beam dosimetry.

Indra J Das, Meisong Ding, George X Ding

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Indra J DasDepartment of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
Meisong DingDepartment of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
George X DingDepartment of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, Tennessee, USA.ORCID https://orcid.org/0000-0002-3700-3024

Funding

SunSILICON
6 · The paper itself

Abstract

backgroundModern radiotherapy relies on advanced treatment techniques that utilize a large number of small fields, for which maintaining dosimetric accuracy is often challenging. Most vendors have introduced microdetectors suitable for small field dosimetry. Sun Nuclear has developed two silicon diodes with a sensitive volume of 0.35 mm PURPOSE: Two Sun Nuclear silicon detectors (unshielded model 1048 and shielded model 1049) are evaluated to characterize their relative dosimetric performance in megavoltage photon beams, with particular emphasis on small fields.

methodsSun Nuclear silicon detectors are identical in physical dimensions except that model 1049 is shielded. These detectors are investigated in Varian TrueBeam photon beams (6 MV, 6 MV FFF, 10 MV, 10 MV FFF and 15 MV) for dose linearity, dose rate linearity, thermal stability, and usability for small fields across multiple photon energies. The measured data are benchmarked against Monte Carlo (MC) simulation using EGSnrc for depth dose, profile and output factors. Additionally small field correction parameters

resultsThese detectors exhibited excellent dose linearity across five photon energies, with only a minor deviation of approximately 1.5% at doses below 2 MU. The dose rate linearity remained stable from 100 MU/Min to highest dose rate for all beam energies with a slight upward trend of 1.5% for lower dose rates. Both detectors are also temperature independent, within 1.0% over the range of 4°C-40°C. Depth dose and profiles measurements showed good agreement with Monte Carlo data across the applicable field size range. For small field dosimetry, shielded detector exhibited a pronounced signal reduction for fields smaller than 2 cm, resulting in large correction factors, whereas the unshielded detector demonstrated favorable and stable performance.

conclusionsBoth silicon diodes have excellent dosimetric characteristics, providing reproducible data with signal linearity. They also provide a large signal (nC). For smallfield photon dosimetry, the unshielded detector yielded superior performance across all investigated energies.

Indexed as

Monte Carlo MethodParticle AcceleratorsPhantoms, ImagingPhotonsRadiometryRadiotherapy Planning, Computer-AssistedSiliconEquipment DesignHumansRadiotherapy DosageSiliconcharacterizationphoton beamsilicon diode detectorsmall field detector

Identifiers

PMID42536490
PMCPMC13426909