Evidence map›Paper›PMID 42535472›Full record

ArticleMedical physics2026

An improved nnUNet with Axial Attention Mechanism and Attention Gated Units for Efficient and Accurate Kidney Segmentation in CT Images.

Malong Tan, Renchao Jin, Xiangyang Xu, Enmin Song

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Malong TanSchool of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Renchao JinSchool of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Xiangyang XuSchool of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Enmin SongSchool of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei, China.

Funding

HUST-UIH-IRI Joint Laboratory Project for Medical Imaging Technology Research and Medical Product Development, China 2021420118000418National Natural Science Foundation of China 72432003National Natural Science Foundation of China 81671768Wuhan Major Science and Technology Project for Breaking Through the Key Bottleneck Technologies, China 2021022002023426
6 · The paper itself

Abstract

backgroundAccurate segmentation of computed tomography (CT) images plays a vital role in surgical planning and therapeutic evaluation for kidney disease diagnosis and treatment. Although nnUNet is widely used in medical image segmentation, its consecutive convolutions suffer from limitations in feature extraction, leading to weight bias and difficulty in effectively modeling long-range dependencies. Additionally, there exists a large semantic gap between encoder and decoder feature maps. Direct feature fusion via skip connections will degrade segmentation accuracy. PURPOSE: This study develops the AAAG-UNet model based on the nnUNet framework by integrating the axial attention mechanism (AAM) and attention gated unit (AGU). Optimized by these two modules, the model overcomes existing technical bottlenecks and effectively improves segmentation performance, offering strong support for the clinical diagnosis of kidney diseases.

methodsThe proposed model integrates axial attention mechanisms into the encoder and attention gated units into the decoder to enhance the capture of long-range spatial dependencies and improve kidney segmentation performance. Specifically, AAM computes self-attention weights along different axes to effectively fuse global information and preserve more spatial details. Additionally, since it performs only local axial attention computation, it maintains stable segmentation performance with low computational cost. Furthermore, AGU is utilized to suppress irrelevant regions, enhance important local features, and eliminate redundant information in CT images, thereby further improving segmentation accuracy.

resultsExperimental results show that our method has remarkable performance in kidney segmentation. On the KiTS19, Kid184 and Kid438 datasets, the model obtains mean Dice values of 0.9639, 0.9712, and 0.9770 for the left kidney, and 0.9660, 0.9742, and 0.9785 for the right kidney, respectively.

conclusionsThe results show that incorporating axial attention mechanisms into the encoder and attention gated units into the decoder of the proposed model can effectively improve kidney segmentation performance.

Indexed as

Image Processing, Computer-AssistedKidneyTomography, X-Ray ComputedHumansattention gated unitsaxial attention mechanismkidney segmentationnnUNet framework

Identifiers

PMID42535472
PMCPMC13425451

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.