ArticleCureus2026
Comparison of the Diagnostic Performance of ACR TI-RADS and EU-TI-RADS for the Detection of Thyroid Malignancy: A Retrospective Study.
Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective The objective of this study was to compare the diagnostic performance of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) and the European Thyroid Imaging Reporting and Data System (EU-TI-RADS) in differentiating benign from malignant thyroid nodules using guideline-based fine-needle aspiration recommendation as the test-positive criterion, and to evaluate demographic and sonographic predictors of thyroid malignancy in a real-world clinical cohort. Materials and methods This retrospective diagnostic accuracy study included thyroid nodules assessed by ultrasound followed by ultrasound-guided fine-needle aspiration cytology (FNAC), with histopathology used as the reference standard for surgically excised nodules. Ultrasound images were independently reviewed by three experienced consultant radiologists blinded to cytological and histopathological outcomes, with consensus used for disagreements. The definitive cohort comprised 809 nodules: 652 benign and 157 malignant. Nodules without a definitive outcome, including nonoperated Bethesda III/IV cases, were excluded from the primary analysis. Bethesda I nodules remained excluded because they were nondiagnostic. Diagnostic performance was calculated using 2 × 2 contingency tables, including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, likelihood ratios, and diagnostic OR (DOR). Paired comparisons were performed using McNemar testing. Multivariable logistic regression was performed to identify independent predictors of malignancy. Sensitivity analyses were performed by classifying excluded nonoperated Bethesda III/IV nodules as benign and malignant in separate scenarios. Results The definitive cohort comprised 809 nodules, including 652 benign nodules and 157 malignant nodules. ACR TI-RADS correctly identified 135 of 157 malignant nodules (sensitivity 85.99%) and correctly excluded 481 of 652 benign nodules (specificity 73.77%). EU-TI-RADS correctly identified 142 of 157 malignant nodules (sensitivity 90.45%) but correctly excluded only 233 of 652 benign nodules (specificity 35.74%). ACR TI-RADS demonstrated higher PPV (44.12% vs 25.31%), NPV (95.63% vs 93.95%), overall accuracy (76.14% vs 46.35%), and DOR (17.26 vs 5.26). EU-TI-RADS had slightly higher sensitivity than ACR TI-RADS (McNemar p = 0.046), whereas ACR TI-RADS had significantly higher specificity (McNemar p < 0.001). Sensitivity analyses including nonoperated Bethesda III/IV nodules yielded similar results. Multivariable logistic regression identified hypoechogenicity, solid or almost entirely solid composition, and taller-than-wide orientation as independent predictors of malignancy, while irregular or lobulated margins and microcalcifications showed quasi-complete separation because of their strong association with malignant nodules. Conclusions Both systems demonstrated high sensitivity and high NPV. In this primary healthcare cohort, ACR TI-RADS provided substantially higher specificity and overall accuracy, suggesting greater potential to reduce unnecessary FNAC, whereas EU-TI-RADS offered marginally higher sensitivity. Hypoechogenicity, solid or almost entirely solid composition, and taller-than-wide orientation were independent predictors of malignancy. Irregular or lobulated margins and microcalcifications were also strongly associated with malignancy but showed quasi-complete separation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.