Evidence map›Paper›PMID 42535023›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Biomechanical comparison of minimally invasive fixation for sanders II calcaneal fractures: a multi-position finite element study from rigid internal fixation to elastic kirschner wire configuration.

Zulong Zhou, Mingxiang Liu, Lingchao Kong, Rende Ning

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zulong Zhou *Department of Orthopedics, The Third Affiliated Hospital of Anhui Medical University (The First People's Hospital of Hefei), Anhui Medical University, Hefei, Anhui, China.
Mingxiang Liu *Department of Orthopedics, The Third Affiliated Hospital of Anhui Medical University (The First People's Hospital of Hefei), Anhui Medical University, Hefei, Anhui, China.
Lingchao KongDepartment of Orthopedics, The Third Affiliated Hospital of Anhui Medical University (The First People's Hospital of Hefei), Anhui Medical University, Hefei, Anhui, China.
Rende NingDepartment of Orthopedics, The Third Affiliated Hospital of Anhui Medical University (The First People's Hospital of Hefei), Anhui Medical University, Hefei, Anhui, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Minimally invasive surgical treatment is increasingly favored for intra-articular displaced calcaneal fractures with a high risk of soft tissue complications. The calcaneus is the largest tarsal bone in the foot and plays a critical role in weight-bearing and gait mechanics; displaced fractures often result in significant functional impairment. Sanders Type II fractures, characterized by a single major fracture line that divides the posterior articular surface into two major bone fragments, are one of the most common subtypes and present a therapeutic challenge in balancing mechanical stability with soft tissue preservation. Methods: A finite element model of Sanders Type II calcaneal fractures was established to compare five fixation methods under physiological tendon loading: (1) a periosteal locking plate, (2) four hollow screws, (3) four K-wires placed along the screw trajectory, (4) two intra-articular K-wires combined with two standard K-wires, and (5) six K-wires placed at dispersed locations. Outcome measures included maximum fragment displacement, implant-induced bone stress, and implant stress. Results: Rigid internal fixation (hollow screws) provided the best initial stability and the least displacement of the bone fragments. A key finding was that under the most severe static loading condition (dorsiflexion with maximum Achilles tendon force), the maximum fragment displacement for all K-wire configurations (≤0.103 mm) was below both the clinically reported acceptable threshold (≤0.5 mm) and the safe healing range (<1 mm), indicating sufficient initial healing stability. Furthermore, K-wires generated significantly lower stress on the bone than the plate, while cannulated screw fixation carried the lowest risk of implant failure. Based on extended observations from clinical literature, K-wire fixation offers potential advantages including a minimally invasive approach, flexible handling, low implant burden, and the possibility of outpatient removal to avoid secondary surgery. Conclusion: Although rigid implants are biomechanically superior, K-wire fixation provides clinically acceptable initial stability and, combined with its minimally invasive characteristics, represents an attractive alternative. The choice of fixation method requires a comprehensive consideration of individual patient factors (such as bone quality and functional demands) and the overall treatment strategy.

Indexed as

biomechanicscalcaneal fracturefinite element analysiskirschner wireminimally invasive surgery

Identifiers

PMID42535023
PMCPMC13422471

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.