Evidence map›Paper›PMID 42528010›Full record

ArticleMagnetic resonance in medicine2026

Fully 3D Unrolled Magnetic Resonance Fingerprinting Reconstruction via Staged Pretraining and Implicit Gridding.

Yonatan Urman, Mark Nishimura, Daniel R Abraham, Xiaozhi Cao, Kawin Setsompop

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Yonatan UrmanDepartment of Electrical Engineering, Stanford University, Stanford, California, USA.ORCID https://orcid.org/0000-0002-5763-8174
Mark NishimuraDepartment of Electrical Engineering, Stanford University, Stanford, California, USA.ORCID https://orcid.org/0000-0003-3976-254X
Daniel R AbrahamDepartment of Electrical Engineering, Stanford University, Stanford, California, USA.ORCID https://orcid.org/0009-0004-4299-3132
Xiaozhi CaoDepartment of Radiology, Stanford University, Stanford, California, USA.ORCID https://orcid.org/0000-0001-5095-648X
Kawin SetsompopDepartment of Electrical Engineering, Stanford University, Stanford, California, USA.ORCID https://orcid.org/0000-0003-0455-7634

Funding

Next generation in-vivo diffusion imaging at submillimeter resolutionR01MH116173 · NIMH · STANFORD UNIVERSITY · PI Yogesh Rathi, Kawin Setsompop · 2018 to 2026
$6.2M
fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution: Administrative SupplementR01EB019437 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO, SETSOMPOP, KAWIN · 2015 to 2024
$5.5M
An acquisition and reconstruction framework to enable mesoscale human fMRI on clinical 3 Tesla scannersR01EB033206 · NIBIB · STANFORD UNIVERSITY · PI SETSOMPOP, KAWIN · 2022 to 2022
$853k
NIBIB NIH HHS R01 EB019437NIBIB NIH HHS R01 EB033206NIH HHS R01 EB019437NIH HHS R01 EB033206NIH HHS R01 MH116173NIMH NIH HHS R01 MH116173
6 · The paper itself

Abstract

purposeMagnetic Resonance Fingerprinting (MRF) enables rapid quantitative imaging, but high-resolution 3D reconstructions remain computationally expensive due to the NUFFTs required at every iteration, and the commonly used Locally Low Rank (LLR) regularization becomes ineffective at high acceleration. Learned 3D priors could address these limitations, but training them at scale is challenging due to memory and runtime constraints. This work proposes SPUR-iG, a fully 3D deep unrolled subspace reconstruction framework that provides fast, high-quality reconstruction for high-resolution non-Cartesian 3D MRF, while keeping training time computationally tractable.

methodsSPUR-iG leverages implicit GROG-based data consistency (DC), which grids non-Cartesian k-space using a learned family of kernels, enabling efficient FFT-based DC with minimal artifacts. To make 3D unrolled training more efficient, we introduce a staged training strategy that keeps computation tractable while progressively improving reconstruction quality. We evaluate the method on a large in vivo dataset, as well as on cross-vendor out-of-distribution data.

resultsAt 1 mm isotropic resolution, SPUR-iG outperforms LLR and a state-of-the-art hybrid 2D-3D unrolled baseline in subspace coefficient quality and

conclusionSPUR-iG introduces a fully 3D unrolled reconstruction framework for MRF that improves both reconstruction speed and accuracy, making high-resolution accelerated 3D MRF more practical for research and clinical use.

Indexed as

BrainImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingAlgorithmsArtifactsHumansdeep learningimage reconstructionmagnetic resonance fingerprintingquantitative MRIunrolled networks

Identifiers

PMID42528010
PMCPMC13527266

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.