Evidence map›Paper›PMID 42525231›Full record

ArticleJournal of echocardiography2026

Agreement of AI-assisted semi-automated right ventricular function analysis using 3D transthoracic echocardiography with artificial intelligence.

Noriko Shiokawa, Masaki Izumo, Yukio Sato, Nina Uenomachi, Motoki Miyauchi, Takanori Okamura, Yoshihiro J Akashi

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of echocardiography, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Noriko ShiokawaUltrasound Center, St. Marianna University Hospital, Kawasaki, Japan.
Masaki IzumoUltrasound Center, St. Marianna University Hospital, Kawasaki, Japan. heartizumo@yahoo.co.jp.ORCID http://orcid.org/0000-0001-8597-1479
Yukio SatoUltrasound Center, St. Marianna University Hospital, Kawasaki, Japan.
Nina UenomachiUltrasound Center, St. Marianna University Hospital, Kawasaki, Japan.
Motoki MiyauchiUltrasound Center, St. Marianna University Hospital, Kawasaki, Japan.
Takanori OkamuraUltrasound Center, St. Marianna University Hospital, Kawasaki, Japan.
Yoshihiro J AkashiUltrasound Center, St. Marianna University Hospital, Kawasaki, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdvances in three-dimensional (3D) transthoracic echocardiography (TTE) with artificial intelligence (AI) enable AI-assisted semi-automated right ventricular (RV) function analysis, including two-dimensional (2D) measurements. However, data on the agreement of these semi-automated analyses in routine clinical practice remain limited. This study evaluates the agreement of AI-based 3D TTE semi-automated measurements compared to manual 2D TTE measurements.

methodsWe enrolled 201 patients who underwent both 2D and 3D TTE between July and November 2023. AI-assisted semi-automated measurements of right ventricular morphology and functional parameters were performed using 3D Auto RV software. While echocardiographic images were acquired manually by the operators in a conventional manner, the AI-assisted analysis was applied specifically during the post-acquisition offline processing stage.

resultsThe feasibility of RV measurement using the AI-based software was 84.8% (201/237) among patients with available 3D datasets, and the overall applicability was 67.4% (201/298) across all consecutive patients undergoing routine echocardiography. Among the 201 analyzed cases, fully automated analysis without manual correction was feasible in 10.9% (22/201), while the remaining 89.1% required manual adjustments of the endocardial borders to ensure clinical accuracy. Time for analysis was significantly shorter with the AI-assisted semi-automated method compared to the manual 2D method (30% reduction, p < 0.001).

conclusionsAI-based 3D TTE semi-automated measurement has the potential to enhance the efficiency and reproducibility of RV function assessment, reducing examiner workload and improving clinical workflow.

Indexed as

Artificial intelligenceRight ventricleRight ventricular functionThree-dimensional echocardiographyTransthoracic echocardiography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.