Evidence map›Paper›PMID 42524570›Full record

ArticleFrontiers in surgery2026

Clinical efficacy and biomechanical analysis of 3D-printed guide plate-assisted cannulated screw fixation compared with conventional fixation in complex acetabular fractures.

Chaoqiang Wang, Xiaoyu He, Zhongyu Zhang, Xueli Li, Mei Wang, Feng Zeng, Caosheng Lai, Huimei Li, Peng Chen, Zhiping Zhou

Abstract read
In one paragraph

Article in Frontiers in surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Chaoqiang WangDepartment of Sports Medicine, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China.
Xiaoyu HeDepartment of Orthopedics, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.
Zhongyu ZhangDepartment of Orthopedics, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.
Xueli LiDepartment of Dermatology, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.
Mei WangDepartment of Orthopedics, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.
Feng ZengDepartment of Orthopedics, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.
Caosheng LaiDepartment of Orthopedics, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.
Huimei LiDepartment of Orthopedics, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.
Peng ChenDepartment of Sports Medicine, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China.
Zhiping ZhouDepartment of Orthopedics, Mindong Hospital Affiliated to Fujian Medical University, Fu'an, Fujian, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Optimal fixation for pelvic and acetabular fractures remains challenging due to competing demands for stability and minimally invasive surgery. This study combined finite element (FE) modeling and a retrospective clinical analysis to compare three fixation strategies. Methods: A three-dimensional FE model of a representative both-column acetabular fracture was constructed to compare cannulated screw-only, plate-only, and combined cannulated screw-plate fixation under simulated standing and sitting conditions. Clinically, patients with acetabular fractures treated between November 2021 and May 2023 were retrospectively grouped into 3D-printed guide plate-assisted cannulated screw plus plate ( Results: FE analysis showed higher stress and displacement under sitting than standing across all constructs, with combined cannulated screw-plate fixation providing better fracture-line displacement control than screw-only fixation, particularly under sitting conditions. Clinically, after multivariable adjustment, the 3D-printed guide group had significantly shorter operative time than the plate-only group and the conventional screw plus plate group (-56.15 min, Conclusions: Combined cannulated screw-plate fixation provides superior biomechanical stability for complex acetabular fractures, while patient-specific 3D-printed guide plate significantly improve perioperative efficiency without compromising short-term safety or functional recovery.

Indexed as

acetabular fracturesbone screwsfinite element analysisinternal fixationthree-dimensional printing

Identifiers

PMID42524570
PMCPMC13412177

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.