Evidence map›Paper›PMID 42524067›Full record

ArticleCureus2026

Biomechanical Evaluation of a Hybrid Fixation Strategy: Enhancing Intramedullary Nail Stability With a Trochanteric Stabilization Plate in Unstable Intertrochanteric Fractures With Lateral Wall Collapse.

Nikhilesh Das, Nithin Shajeendran, Swathy G Nurani, Pranav Thaker, Nikunj Patel, Sudipto Mukherjee

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nikhilesh DasDepartment of Orthopaedics, Peerless Hospital and B.K. Roy Research Centre, Kolkata, IND.
Nithin ShajeendranDepartment of Design and Development, Miraclus Orthotech Pvt. Ltd., Vavdi, IND.
Swathy G NuraniDepartment of Design and Development, Miraclus Orthotech Pvt. Ltd., Vavdi, IND.
Pranav ThakerDepartment of Design and Development, Miraclus Orthotech Pvt. Ltd., Vavdi, IND.
Nikunj PatelDepartment of Design and Development, Miraclus Orthotech Pvt. Ltd., Vavdi, IND.
Sudipto MukherjeeDepartment of Orthopaedics, Peerless Hospital and B.K. Roy Research Centre, Kolkata, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Unstable reverse oblique intertrochanteric fractures with lateral wall collapse present a unique fixation challenge due to the absence of a lateral buttress. When treated with standard implants, this structural deficit frequently leads to construct failure through varus malunion and medialization of the femoral shaft. A device developed to provide rigidity for the maintenance of fracture reduction would bridge this gap. This study evaluates the biomechanical performance of a hybrid fixation strategy utilizing a Trochanteric Stabilization Plate for Nails (TSPN) in combination with an intramedullary nail (IMN) for such fractures using finite element analysis (FEA) and mechanical testing. Methods The study compared standard IMN fixation to a hybrid IMN-TSPN construct by simulating fracture scenarios in a validated femur model and performing mechanical tests on composite bone specimens (total n = 10; n = 5 per group). Finite element analysis quantified computational deformation, stress distribution, and elastic strain, while experimental physical tests measured construct stiffness and failure load under static axial compression. Statistical significance for experimental outcomes was evaluated using the non-parametric Mann-Whitney U test with a Bonferroni correction. Results The IMN-TSPN hybrid construct demonstrated a significant 1.85-fold increase in experimental structural rigidity (p = 0.008) and higher physical failure thresholds compared to IMN alone. Computationally, TSPN augmentation substantially reduced maximum fracture-gap displacement, peak elastic strain, and peak von Mises stress. The TSPN effectively redistributed loading and minimized total construct deformation. Conclusion In a composite bone model under static axial loading, augmenting an IMN with a TSPN significantly increased construct stiffness and reduced deformation compared to IMN alone. These findings suggest a biomechanical advantage that warrants further testing in clinically representative, dynamic models.

Indexed as

biomechanical testingcomputational modellingfinite element analysishybrid fixationintertrochanteric fracture

Identifiers

PMID42524067
PMCPMC13408530

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked