Evidence map›Paper›PMID 42521420›Full record

ArticleMagnetic resonance in medicine2026

Regularized Joint Reconstruction and Slab Combination for Accelerated Three-Dimensional Multi-Slab Diffusion-Weighted Imaging Using Multi-Scale Energy Models.

Reza Ghorbani, Jyothi Rikhab Chand, Chu-Yu Lee, Mathews Jacob, Merry Mani

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Reza GhorbaniDepartment of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia, USA.ORCID https://orcid.org/0000-0001-8997-1273
Jyothi Rikhab ChandDepartment of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia, USA.ORCID https://orcid.org/0000-0002-8335-6103
Chu-Yu LeeDepartment of Radiology, University of Iowa, Iowa City, Iowa, USA.ORCID https://orcid.org/0000-0001-5288-3309
Mathews JacobDepartment of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia, USA.ORCID https://orcid.org/0000-0001-6196-3933
Merry ManiDepartment of Radiology and Medical Imaging, and Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.ORCID https://orcid.org/0000-0001-8602-1109

Funding

University of Iowam - Whole Body 7T MRI ScannerS10RR028821 · NCRR · UNIVERSITY OF IOWA · PI MAGNOTTA, VINCENT A · 2010 to 2010
$8.0M
University of Iowa – 3T ESP MRI ScannerS10OD030220 · OD · UNIVERSITY OF IOWA · PI MAGNOTTA, VINCENT A · 2021 to 2021
$1.9M
University of Iowa - Research 3T MRI Connectome UpgradeS10OD025025 · OD · UNIVERSITY OF IOWA · PI MAGNOTTA, VINCENT A · 2018 to 2018
$1.9M
Fast Multi-dimensional Diffusion MRI with Sparse Sampling and Model-basedDeep Learning ReconstructionR01EB031169 · NIBIB · UNIVERSITY OF VIRGINIA · PI MANI, MERRY · 2021 to 2024
$1.7M
NCRR NIH HHS S10 RR028821NIBIB NIH HHS 1S10OD025025-01NIBIB NIH HHS 1S10OD030220-01NIBIB NIH HHS 1S10RR028821-01NIBIB NIH HHS R01 EB031169NIH HHS EB031169-02S1NIH HHS R01 EB031169NIH HHS S10 OD025025NIH HHS S10 OD030220
6 · The paper itself

Abstract

purposeTo jointly reconstruct high-resolution diffusion-weighted volumes and eliminate slab-boundary artifacts while preserving fine anatomical detail from undersampled 3D multi-slab k-space acquisitions.

methodsA bilinear forward model was formulated to describe the 3D multi-slab acquisition, treating the image volume and slab excitation profiles as joint variables. A maximum a posteriori framework optimized a cost function with a Gaussian data-fidelity term, a CNN-based deep energy prior guiding accelerated recovery, and a quadratic regularization term anchoring the slab profiles to an initial estimate. The energy-based prior models the negative log distribution of clean diffusion-weighted images, while its gradient guides the accelerated reconstruction toward the artifact-free distribution. The resulting non-convex problem was solved via alternating minimization, where the image volume was updated through a majorize-minimize scheme with conjugate gradient optimization, and slab profiles were estimated through regularized least-squares optimization.

resultsThe proposed Energy-based Profile Encoding (EPEN) framework substantially reduced slab-boundary artifacts compared with conventional slab-boundary correction approaches. Improved structural consistency and contrast preservation were achieved across multiple acceleration factors and slab configurations.

conclusionEPEN enables robust joint 3D multi-slab diffusion MRI reconstruction with slab profile correction within an alternating optimization framework using deep energy-based image priors.

Indexed as

BrainDiffusion Magnetic Resonance ImagingImage Processing, Computer-AssistedImaging, Three-DimensionalAlgorithmsArtifactsConvolutional Neural NetworksHumansPhantoms, Imaging3D multi‐slab diffusion MRIboundary artifact correctionmulti‐scale energy model

Identifiers

PMID42521420
PMCPMC13527291

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.