Evidence map›Paper›PMID 42519894›Full record

ArticleMedical physics2026

Transformer-based rapid dose calculation for carbon ion therapy.

Yinuo Liu, Yang Hu, Pengbo He, Yongtao Zhao, Qiang Li

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yinuo LiuSchool of Future Technology, Xi'an Jiaotong University, Xi'an, China.
Yang HuSchool of Future Technology, Xi'an Jiaotong University, Xi'an, China.
Pengbo HeInstitute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China.
Yongtao ZhaoSchool of Future Technology, Xi'an Jiaotong University, Xi'an, China.
Qiang LiInstitute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China.

Funding

the Key Research and Development Program of Gansu Province 23YFFA0010the National Natural Science Foundation of China 12375354Top Talents Project of Gansu Province 2023-9Youth Innovation Promotion Association, Chinese Academy of Sciences Y2023113
6 · The paper itself

Abstract

backgroundOnline adaptive radiotherapy (OART) improves the precision of carbon ion therapy by enabling dynamic treatment plan adjustment. However, its implementation is critically constrained by the limited development of fast and accurate dose engines for both plan adjustment and online verification. PURPOSE: To address these challenges, this study advances per-beam carbon ion artificial intelligence (AI) dose engines toward clinical use by establishing an end-to-end workflow from per-beam calculation to full-plan accumulated dose evaluation, and by conducting a controlled comparison between Transformer and Long Short-Term Memory (LSTM) sequence backbones to assess their relative suitability for this task.

methodsThe system incorporates CT-block generation, per-beam dose calculation, and dose accumulation and is developed for evaluation on the Heavy Ion Medical Machine (HIMM). The patient's three-dimensional (3D) CT is decomposed into multiple CT-blocks to represent pencil beam energy deposition. A DoTA-style Transformer model (Ci-DoTA) takes CT-blocks and explicit beam energies as inputs to calculate MC-equivalent 3D per-beam dose, which is then weighted and summed into a full-plan dose. An LSTM baseline model (Ci-DoLSTM) is implemented with identical input/output definitions and training settings. The implemented models are evaluated against a Pencil Beam Algorithm (PBA) and Monte Carlo (MC) dose calculations on head-and-neck (H&N) cases at both per-beam and full-plan levels using γ analysis, voxel-wise error metrics, and runtime.

resultsCi-DoTA and Ci-DoLSTM achieved high per-beam agreement with MC. Under γ (3%, 3 mm), the mean pass rates were 99.85% (Ci-DoTA) and 99.06% (Ci-DoLSTM). Under γ (1%, 1 mm), the gap widened, with mean pass rates of 98.01% and 94.29%, respectively. Full-plan evaluation on all six test patients showed consistently high agreement for Ci-DoTA, with γ (3%, 3 mm) ranging from 99.04% to 99.76% and γ (1%, 1 mm) ranging from 92.88% to 94.42%. Dose differences were spatially localized and primarily clustered near steep gradients and density interfaces, including the lateral penumbra and distal fall-off. CT HU Gradient Intensity (CHGI) was negatively associated with γ (1%, 1 mm), with a breakpoint at 625.53 HU/mm and limited explained variance (R

conclusionsBoth deep learning engines support near real-time carbon ion dose calculation at the pencil beam scale. The Transformer backbone achieves higher agreement, while the LSTM backbone is faster per beam. These results support the feasibility of fast dose recalculation in carbon ion workflows, and suggest that calculation difficulty for Ci-DoTA increases in anatomically heterogeneous CT-blocks, although additional factors beyond CHGI remain influential.

Indexed as

Heavy Ion RadiotherapyRadiation DosageRadiotherapy Planning, Computer-AssistedHumansLong Short Term MemoryMonte Carlo MethodRadiotherapy DosageTime FactorsTomography, X-Ray Computedcarbon ion therapydeep learningdose calculationLSTMMonte Carlotransformer

Identifiers

PMID42519894
PMCPMC13411663

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.