Evidence map›Paper›PMID 42519808›Full record

ArticleJournal of experimental orthopaedics2026

Final intraoperative gaps commonly exceed resection-based reference gaps during sequential balancing in imageless robot-assisted total knee arthroplasty.

Yugo Morita, Jonggu Shin, Mohammed El-Hassan, Ittai Shichman, William J Long, Peter K Sculco

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yugo MoritaComplex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York New York USA.
Jonggu ShinComplex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York New York USA.
Mohammed El-HassanComplex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York New York USA.
Ittai ShichmanComplex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York New York USA.
William J LongComplex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York New York USA.
Peter K SculcoComplex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York New York USA.ORCID https://orcid.org/0000-0001-7050-5571

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purposes of this study were to quantify final-minus-reference gap difference in the medial and lateral compartments in extension and flexion during passive, imageless robot-assisted total knee arthroplasty (RA-TKA) and to identify preoperative radiographic and initial intraoperative factors associated with greater final-minus-reference gap difference. Methods: A retrospective single-surgeon series of 379 primary total knee arthroplasties performed using a passive, imageless robot-assisted system for osteoarthritis was analysed. Medial and lateral compartment spaces were recorded in extension and at 90° flexion before bone resection and after trial implantation. For each compartment and knee position, the reference gap was defined from the initial gap, validated resection depth, femoral component thickness and tibial-side construct thickness. Multivariable linear regression models were adjusted for age, body mass index, sex and implant design, with cluster-robust standard errors to account for bilateral knees. Results: Mean final-minus-reference gap difference was positive in all four conditions, indicating that final gaps exceeded the calculated reference in both extension and flexion: 4.7 ± 2.1 mm medially and 3.4 ± 2.8 mm laterally in extension, and 4.2 ± 3.0 mm medially and 3.2 ± 3.7 mm laterally in flexion. Smaller initial compartment gaps and greater varus-valgus laxity range were consistently associated with greater gap difference. Posterior-stabilized design was associated with greater medial gap difference in extension and with greater medial and lateral gap difference in flexion. More valgus alignment and greater lateral osteophyte burden were associated with greater lateral gap difference. Conclusions: In passive, imageless RA-TKA, final measured gaps commonly exceeded a resection-based reference during sequential balancing. Smaller initial compartment gaps and greater varus-valgus laxity range were consistently associated with greater gap difference. These findings suggest that resection-based preresection gap estimates should be interpreted with awareness of compartment-specific tightness and coronal laxity. Level of Evidence: Level III, retrospective cohort study.

Indexed as

gap balancinglaxityosteophytesrobot‐assistedtotal knee arthroplasty

Identifiers

PMID42519808
PMCPMC13384344

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked