Evidence map›Paper›PMID 42518542›Full record

ArticleFrontiers in endocrinology2026

Comparison of the effectiveness of autofluorescence devices in the detection of parathyroid glands during thyroid operations: a propensity score matched analysis (PSM).

Nikolaos Voloudakis, Eleni Lazaridou, Stefanos Atmatzidis, Evangelia Bellou, Maria Velikoudi, Anestis Basios, Basileios Papaziogas, Ioannis Koutelidakis

Abstract readComparative Study
In one paragraph

Article in Frontiers in endocrinology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nikolaos VoloudakisSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Eleni LazaridouSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Stefanos AtmatzidisSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Evangelia BellouSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Maria VelikoudiSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Anestis BasiosSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Basileios PapaziogasSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Ioannis KoutelidakisSecond Surgical Department, G. Gennimatas General Hospital of Thessaloniki, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: In recent years, an abundance of evidence has supported the use of specialized autofluorescence devices to assist in detecting parathyroid glands (PGs) during thyroid surgery. This study compares the "naked eye" (NE) method with an alternative device (IMAGE1 S™ Rubina Methods: From 01/01/2024 to 31/08/2025, data from all patients undergoing thyroid-related surgery were collected from a prospectively maintained database. Adult patients who had total thyroidectomy with or without bilateral central neck dissection were included. Patients with concurrent hyperparathyroidism or renal insufficiency were excluded. In the intervention groups, the IMAGE1 S™ Rubina Results: 292 patients were included in the study. Propensity Score Matching yielded 37 patients per group, with no differences in demographic or clinical features. Ordinal logistic regression for the number of parathyroid glands identified showed higher odds of better gland identification with Rubina Conclusion: Detection rates of parathyroid glands improved with the use of both autofluorescence devices compared to the naked eye, while there was no significant decrease in postoperative hypoparathyroidism rates.

Indexed as

Optical ImagingParathyroid GlandsThyroidectomyThyroid GlandAdultAgedFemaleHumansMaleMiddle AgedPropensity ScoreRetrospective Studiesautofluorescenceintraoperative preservationnaked eyeNIRAFparathyroidthyroid surgery

Identifiers

PMID42518542
PMCPMC13381608

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.