ArticleFrontiers in robotics and AI2026
PALPABLE: enhanced bending stiffness and proprioception in soft actuators for laparoscopic palpation.
Article in Frontiers in robotics and AI, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The assessment of tissue properties via direct palpation is essential for localizing abnormalities during surgery. However, Minimally Invasive Surgery (MIS) eliminates this tactile feedback, creating a critical sensory gap. To address this, the EU Horizon project PALPABLE is developing novel fiber-optic sensing modalities for stiffness assessment. Successful integration of this technology requires an articulation interface that balances high maneuverability with the structural stability necessary for deflection-free tissue palpation. We present a single-degree-of-freedom (DOF) soft silicone actuator integrated with a modular, bioinspired passive stiffening element. Mechanical loading tests, motion tracking, and Finite Element Method (FEM)-guided design iterations validate the stiffening strategy and actuator performance. The design achieves a substantial increase in bending stiffness, improving the stiffness-pressure response by 8-fold relative to the unstiffened actuator under critical loading (normal force at a 90° bend). Furthermore, we developed a compact, custom pneumatic syringe pump with closed-loop pressure control to ensure precise, safe operation in surgical environments. By combining embedded fiber-optic sensing with machine-learning models, the system achieves free-space full-shape reconstruction with approximately 1% error. This work delivers a compact, load-capable, and sensorized soft actuator tailored for PALPABLE's probe manipulation requirements, enabling safe, controllable, and data-rich tissue palpation in confined anatomical spaces.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.