Evidence map›Paper›PMID 42516776›Full record

ArticleOxford medical case reports2026

Charging failure due to pulse generator rotation after deep brain stimulation: a case report.

Di Lu, Mingming Zhao, Feng Yin

Abstract readCase Reports
In one paragraph

Article in Oxford medical case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Di LuDepartment of Neurosurgery, Aerospace Center Hospital, No. 15 Yuquan Road, Haidian District, Beijing 100049, China.ORCID https://orcid.org/0009-0002-5499-260X
Mingming ZhaoDepartment of Neurosurgery, Aerospace Center Hospital, No. 15 Yuquan Road, Haidian District, Beijing 100049, China.ORCID https://orcid.org/0000-0001-9668-5267
Feng YinDepartment of Neurosurgery, Aerospace Center Hospital, No. 15 Yuquan Road, Haidian District, Beijing 100049, China.ORCID https://orcid.org/0000-0003-1793-7994

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A 54-year-old man with Parkinson's disease presented with gait instability and difficulty charging his rechargeable deep brain stimulation (DBS) pulse generator. Chest radiography revealed horizontal rotation and anterior-to-posterior inversion of the device within the subcutaneous pocket, which was not seen in prior imaging. Surgical revision confirmed the device malorientation, and repositioning restored charging efficiency. This case highlights that pulse generator rotation, a rare but relevant hardware complication, can cause charging difficulties despite normal device interrogation. It underscores the importance of considering mechanical causes and using chest imaging in postoperative assessments.

Indexed as

deep brain stimulationdevice rotationhardware complicationParkinson’s diseaserechargeable implanted pulse generator

Identifiers

PMID42516776
PMCPMC13403564

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.