Evidence map›Paper›PMID 42515518›Full record

ArticleSensors (Basel, Switzerland)2026

Toward Robust EEG Classification Using Adaptive CNN-Transformer and Inception Architectures and Signal Level Augmentation.

Vikas Reddy Venkannagari, Shivansh Sharma, Parthan Olikkal, Dev Parikh, Jay Paun, Farshad Safavi, Ramana Vinjamuri

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Vikas Reddy VenkannagariDepartment of Computer Science and Electrical Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
Shivansh SharmaDepartment of Computer Science and Electrical Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.ORCID 0009-0000-2232-8718
Parthan OlikkalDepartment of Computer Science and Electrical Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.ORCID 0000-0002-5513-1150
Dev ParikhDepartment of Computer Science and Electrical Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.ORCID 0009-0000-4615-5823
Jay PaunDepartment of Computer Science and Electrical Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.ORCID 0009-0009-7482-5519
Farshad SafaviDepartment of Computer Science and Electrical Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
Ramana VinjamuriDepartment of Computer Science and Electrical Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.ORCID 0000-0003-1650-5524

Funding

National Science Foundation CAREER Award HCC- 2053498
6 · The paper itself

Abstract

Non-invasive electroencephalography (EEG) enables practical brain-state monitoring for applications such as emotion recognition and event-related potential (ERP)-based deception detection. However, robust EEG classification remains challenging because of noise, non-stationarity, limited labeled data, and substantial inter-subject variability. In this work, we present a sensor-density-aware framework that applies different deep architectures to low- and high-channel EEG acquisition settings and augments the training data using a physiologically constrained signal-level procedure. For the 5-channel LieWaves dataset, the CNN-Transformer achieved 97.14±1.36% subject-dependent accuracy with augmentation, compared with 92.91±4.34% without augmentation. For the 62-channel SEED dataset, the Inception CNN achieved 98.52±0.79% with augmentation and 98.44±0.83% without augmentation. The improvement on LieWaves was statistically significant, whereas the small improvement on SEED was not statistically significant. Under subject-independent evaluation, performance was 57.83±8.96% on LieWaves with augmentation and 57.95±8.38% on SEED. These results demonstrate strong subject-dependent performance while confirming that cross-subject generalization remains challenging. Overall, the proposed framework combines sensor-density-aware architecture selection with signal-level augmentation and provides a systematic comparison of subject-dependent and subject-independent EEG classification.

Indexed as

ElectroencephalographySignal Processing, Computer-AssistedAlgorithmsBrainConvolutional Neural NetworksHumansconvolutional neural networkdata augmentationelectroencephalographyemotion recognitionP300-based deception detectiontransformer

Identifiers

PMID42515518
PMCPMC13416870

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.