Evidence map›Paper›PMID 42515477›Full record

ArticleSensors (Basel, Switzerland)2026

Interpretable Calibration Transfer and Drift Compensation for MOS Gas Sensors in Complex Gas Mixtures.

Julian Schauer, Jannis Morsch, Dennis Arendes, Andreas Schütze, Christian Bur

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Julian SchauerLaboratory for Measurement Technology, Saarland University, 66123 Saarbruecken, Germany.ORCID 0009-0002-2830-1166
Jannis MorschLaboratory for Measurement Technology, Saarland University, 66123 Saarbruecken, Germany.
Dennis ArendesLaboratory for Measurement Technology, Saarland University, 66123 Saarbruecken, Germany.
Andreas SchützeLaboratory for Measurement Technology, Saarland University, 66123 Saarbruecken, Germany.ORCID 0000-0003-3060-5177
Christian BurLaboratory for Measurement Technology, Saarland University, 66123 Saarbruecken, Germany.ORCID 0000-0003-2177-3646

Funding

Bundesministerium für Forschung, Technologie und Raumfahrt 16ME0572K
6 · The paper itself

Abstract

This study presents a novel approach for model-based calibration transfer and drift compensation for metal oxide semiconductor (MOS) gas sensors. The sensors are lab-calibrated and different calibration models for each of the eight volatiles contained in the calibration are trained to allow for an interpretable quantification of individual volatiles in complex mixtures. Calibration transfer and drift compensation are used to compensate for domain shifts that particularly affect the model accuracy. Here, several domain shifts are considered, e.g., sensor-to-sensor variation among different production batches (calibration transfer) or time-related changes in sensor response like poisoning and aging (drift compensation). Such domain shifts can lead to a substantial performance degradation and are critical for reliable field deployment. Since interpretable and robust machine learning algorithms based on feature extraction, feature selection, and regression (FESR) are not inherently capable of model-based calibration transfer and drift compensation, recalibration typically requires time-consuming and labor-intensive laboratory calibration procedures. To address this challenge, a novel approach represents the interpretable FESR machine learning models as a deep neural network (IDNNRep), enabling the application of transfer learning techniques from the field of deep neural networks (DNNs). This allows the reuse of knowledge gained in an initial calibration domain and facilitates model transfer using only a small amount of new calibration data, thereby reducing calibration effort and time. The proposed method is evaluated across multiple gases, including acetone and toluene, for four domain-shift scenarios and compared with FESR models retrained exclusively on data from the new domain and orthogonal signal correction (OSC). The results demonstrate that the proposed approach reduces the root mean square error (RMSE) compared to the initial model, achieving values of 18.0-28.0 ppb (normalized RMSE: 6.3-9.3%) for both gases with only 0.1 of the calibration data, resulting in a reduction of up to 93% compared to the initial calibration model and 89% compared to the OSC. Furthermore, due to the interpretable nature of the underlying FESR structure, the calibration transfer enables additional sensor- and gas-specific insights.

Indexed as

calibration transferinterpretable machine learninglaboratory calibrationMOS gas sensorsneural network representationtransfer learning

Identifiers

PMID42515477
PMCPMC13418999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.