Evidence map›Paper›PMID 42515371›Full record

ArticleSensors (Basel, Switzerland)2026

CFD-Guided Shadowing-Aware Acoustic Path Selection for Accurate Wind Estimation in Ultrasonic Anemometers.

Tien Minh Khoi Nguyen, Tan Dung Nguyen, Le The Anh Vi, Thanh Dat Le, Thanh Dam Nguyen, Minh Quan Nguyen, Jae Sung Ahn, Tan Tien Nguyen, Sudip Mondal, Vu Hoang Minh Doan and 2 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Tien Minh Khoi NguyenIndustry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0009-0004-3498-8528
Tan Dung NguyenFaculty of Engineering, Vietnamese-German University, Ho Chi Minh City 700000, Vietnam.ORCID 0000-0002-2389-8875
Le The Anh ViIndustry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0009-0002-0860-5904
Thanh Dat LeIndustry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0009-0004-8888-2614
Thanh Dam NguyenIndustry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0009-0001-1691-9738
Minh Quan NguyenIndustry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0009-0000-4102-9705
Jae Sung AhnSmart Gym-Based Translational Research Center for Active Senior's Healthcare, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0000-0002-5107-0848
Tan Tien NguyenKey Laboratory of Digital Control and System Engineering (DCSELab), Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), Ho Chi Minh City 700000, Vietnam.ORCID 0000-0001-7943-1994
Sudip MondalDigital Healthcare Research Center, Institute of Information Technology and Convergence, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0000-0002-0638-9657
Vu Hoang Minh DoanSmart Gym-Based Translational Research Center for Active Senior's Healthcare, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0009-0003-6393-9883
Jaeyeop ChoiSmart Gym-Based Translational Research Center for Active Senior's Healthcare, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0000-0003-2370-3318
Junghwan OhIndustry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0000-0002-5837-0958

Funding

Global Joint Research Program funded by Pukyong National University 202412240001National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) No. 2022R1A5A8023404
6 · The paper itself

Abstract

Ultrasonic anemometers are widely used for wind measurement owing to their fast response, high temporal resolution, and long operational lifetime with minimal recalibration requirements. However, most configurations suffer from transducer shadowing, where cylindrical probes disrupt local airflow and introduce systematic errors in time-of-flight (TOF) measurements. While prior computational fluid dynamics (CFD)-based investigations have characterized this effect, their analyses remain confined to low wind speeds, and no existing study has explicitly proposed a method to mitigate shadowing-induced bias. This paper presents a coupled CFD and acoustic propagation framework to analyze wake-induced velocity deficits and their effects on TOF measurements for a three-transducer ultrasonic anemometer, with simulations spanning 5 to 75 m/s over the full 360° range. The results show that shadowing distortions are strongly direction-dependent, peaked within approximately ±5° angular sectors, with a near-constant velocity deficit of approximately 40% along affected paths. A shadowing-aware acoustic path selection method is then proposed that selectively excludes corrupted acoustic paths, reducing the average velocity root-mean-square error (RMSE) to 0.349 m/s and the directional RMSE to 1.14°, representing improvements of more than an order of magnitude over shadow-unaware methods. These findings provide a physically grounded, simulation-based framework for shadowing-aware wind measurement using ultrasonic anemometers.

Indexed as

acoustic propagationcomputational fluid dynamicstransducer shadowingultrasonic anemometerwind measurement

Identifiers

PMID42515371
PMCPMC13417252

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.