Cross-Verification and Consistency Evaluation of Monochromator-Based Radiance Calibration Systems Under Varying Bandwidths Against an SI-Traceable Reference.

Kaichao Lei, Hongjia Xu, Xin Ye, Jingying Yue, Ye Jiang, Shuqi Li, Yachao Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kaichao LeiSchool of Science, Changchun Institute of Technology, Changchun 130012, China.
Hongjia XuChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Xin YeChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0000-0001-6735-5939
Jingying YueSchool of Science, Changchun Institute of Technology, Changchun 130012, China.
Ye JiangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Shuqi LiChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Yachao ZhangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.

Funding

National Key R&D Program of China Grant No. 2022YFF0610802
6 · The paper itself

Abstract

High-precision absolute radiometric calibration is the cornerstone of space-based quantitative remote sensing. Monochromator-based radiance calibration is a key approach for space-borne radiometric benchmark transfer; however, the influence of the monochromator bandwidth on calibration accuracy urgently requires validation via an independent, SI-traceable benchmark. Taking a spectrometer as a case study, this paper establishes an equivalent theoretical calibration model. The model reveals that discrepancies in the equivalent spectral distributions of the calibration sources primarily contribute to their calibration deviations. Within the 775-855 nm range, cross-comparison experiments were conducted between the monochromator facility and a reference standard lamp-plaque. Experimental results demonstrate that under bandwidth configurations of 2 nm, 4 nm, and 6 nm, relative deviations in calibrated radiance responsivity stabilize at approximately 2.3%, exhibiting no significant dependence on bandwidth variations. Crucially, the consistency between the two methodologies is rigorously verified, as the radiance responsivity ratios uniformly fall within the combined expanded measurement uncertainty bounds. By demonstrating that bandwidth expansion within the specified 2-6 nm range does not degrade calibration accuracy, this study provides a critical empirical basis for safely increasing solar monochromator bandwidths to improve the signal-to-noise ratio (SNR) in next-generation benchmark missions like the Space-based Radiometric Measurement Benchmark Mission (LIBRA) program.