Evidence map›Paper›PMID 42515306›Full record

ArticleSensors (Basel, Switzerland)2026

A Single-IMU Wearable System with 1D U-Net for Knee Adduction Moment Waveform Reconstruction During Gait.

Hiroko Sakamoto, Hiroshi Yoshihara, Ayako Akiba, Kohei Nishizawa, Masaki Nagashima, Kengo Harato, Takeo Nagura, Masaya Nakamura

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hiroko SakamotoDepartment of Orthopaedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.ORCID 0009-0005-6109-8384
Hiroshi YoshiharaDepartment of Health Economics and Outcomes Research, Graduate School of Pharmaceutical Sciences, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan.ORCID 0000-0001-5297-3822
Ayako AkibaDepartment of Orthopaedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.ORCID 0009-0006-6805-5456
Kohei NishizawaDepartment of Orthopaedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.ORCID 0000-0002-5060-6444
Masaki NagashimaDepartment of Orthopaedic Surgery, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-ku, Tokyo 108-8329, Japan.ORCID 0000-0002-5954-1536
Kengo HaratoSports Medicine Research Center, Keio University, 4-1-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa 223-8521, Japan.ORCID 0000-0003-1796-2823
Takeo NaguraDepartment of Clinical Biomechanics, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Masaya NakamuraDepartment of Orthopaedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.ORCID 0000-0002-2279-7028

Funding

Hisamitsu Pharmaceutical Endowed Research Laboratory for Clinical Biomechanics. S01PD96002
6 · The paper itself

Abstract

The knee adduction moment (KAM) is an important biomechanical marker of medial knee joint loading, but conventional assessment requires laboratory-based motion analysis. This study aimed to develop and evaluate an improved inertial measurement unit (IMU)-based KAM estimation system that incorporates a one-dimensional U-Net (1D U-Net) with a gated recurrent unit (GRU) bottleneck. Gait data from 50 participants were used for model development and internal evaluation, and an independent holdout dataset collected using the same study protocol included 45 participants. Simultaneously recorded IMU signals and reference KAM obtained from motion capture-based inverse dynamics were used for training and evaluation. The model used a single IMU attached to the tibial tuberosity to reconstruct the KAM waveform during the stance phase. For peak KAM, Pearson's r values were 0.819, 0.602, and 0.621 for the training, internal validation, and holdout datasets, respectively. For KAM impulse, the corresponding values were 0.941, 0.744, and 0.745. These findings indicate that a simplified wearable system combining a single tibial IMU with a 1D U-Net incorporating a GRU bottleneck can reconstruct the KAM waveform during walking and derive clinically relevant parameters from it. Although further improvement in prediction accuracy is required, this framework may provide a practical basis for simplified screening or monitoring of medial knee loading in settings closer to routine clinical practice.

Indexed as

GaitKnee JointWearable Electronic DevicesAdultBiomechanical PhenomenaFemaleHumansMaleMotion Capture1D U-Netbiomechanical assessmentgait analysisindependent holdout validationinertial measurement unitknee adduction momentknee osteoarthritismachine learningwaveform reconstructionwearable sensor

Identifiers

PMID42515306
PMCPMC13416722

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.