ArticleSensors (Basel, Switzerland)2026
Design of a Distance-Compensated Infrared Thermometer for Canopy Temperature Monitoring.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Infrared (IR) thermometry is essential for non-contact surface temperature monitoring in precision agriculture, but conventional single-pixel devices exhibit distance-dependent measurement errors that hinder field deployment. Most existing solutions require either fixed-geometry installations, post-processing corrections, or expensive thermal imaging systems with computational overhead. This paper presents the design, development, and evaluation of an IR thermometer measurement system that implements a lightweight signal processing algorithm for distance compensation. The instrumentation module integrates the thermometer's temperature signal with ultrasonic distance measurements and employs a distance-bias lookup table (LUT) calibrated at regulated setpoints. Real-time signal conditioning through bilinear interpolation generates corrected temperature outputs. Under controlled reference-target conditions, system evaluation across 5-200 cm shows that uncompensated errors reach approximately -5 °C at 200 cm, whereas the proposed signal processing reduces the distance-dependent residual RMSE to below 0.20 °C over the tested range. The instrument also preserves short-term repeatability, with standard deviations between 0.08 °C and 0.12 °C across stand-off distances from 20 to 200 cm. By delivering distance-invariant measurements through external signal processing, the system is designed to support flexible, height-independent deployment of single-pixel IR thermometry for precision agriculture applications such as canopy temperature monitoring. A preliminary field measurement on a live tree canopy under one overcast condition provides initial evidence that the distance-dependent drift can be reduced outdoors, with the compensated output remaining within 0.7 °C of an external handheld reference across the 5-200 cm range; comprehensive multi-condition field validation remains necessary in future work.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.