Evidence map›Paper›PMID 42515264›Full record

ArticleSensors (Basel, Switzerland)2026

Design of a Distance-Compensated Infrared Thermometer for Canopy Temperature Monitoring.

Liem H T Nguyen, Manu Chilukuri, Christopher D Delhom, Prasanna Gowda, Sungyong Jung, Hyusim Park

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Liem H T NguyenMcComish Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD 57007, USA.ORCID 0000-0001-9137-2843
Manu ChilukuriDepartment of Electrical Engineering, University of Texas at Arlington, Arlington, TX 76019, USA.
Christopher D DelhomNational Center for Alluvial Aquifer Research, USDA Agricultural Research Service, Stoneville, MS 38776, USA.ORCID 0000-0001-5111-5818
Prasanna GowdaSmart Agriculture Research Center, University of Texas at Arlington, Arlington, TX 76019, USA.ORCID 0000-0001-8782-6953
Sungyong JungMcComish Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD 57007, USA.
Hyusim ParkDepartment of Electrical Engineering, University of North Texas, Denton, TX 76203, USA.ORCID 0000-0001-8190-0016

Funding

United States Department of Agriculture 58-6066-4-032
6 · The paper itself

Abstract

Infrared (IR) thermometry is essential for non-contact surface temperature monitoring in precision agriculture, but conventional single-pixel devices exhibit distance-dependent measurement errors that hinder field deployment. Most existing solutions require either fixed-geometry installations, post-processing corrections, or expensive thermal imaging systems with computational overhead. This paper presents the design, development, and evaluation of an IR thermometer measurement system that implements a lightweight signal processing algorithm for distance compensation. The instrumentation module integrates the thermometer's temperature signal with ultrasonic distance measurements and employs a distance-bias lookup table (LUT) calibrated at regulated setpoints. Real-time signal conditioning through bilinear interpolation generates corrected temperature outputs. Under controlled reference-target conditions, system evaluation across 5-200 cm shows that uncompensated errors reach approximately -5 °C at 200 cm, whereas the proposed signal processing reduces the distance-dependent residual RMSE to below 0.20 °C over the tested range. The instrument also preserves short-term repeatability, with standard deviations between 0.08 °C and 0.12 °C across stand-off distances from 20 to 200 cm. By delivering distance-invariant measurements through external signal processing, the system is designed to support flexible, height-independent deployment of single-pixel IR thermometry for precision agriculture applications such as canopy temperature monitoring. A preliminary field measurement on a live tree canopy under one overcast condition provides initial evidence that the distance-dependent drift can be reduced outdoors, with the compensated output remaining within 0.7 °C of an external handheld reference across the 5-200 cm range; comprehensive multi-condition field validation remains necessary in future work.

Indexed as

distance compensationinfrared thermometryprecision agriculturesurface temperatureultrasonic sensor

Identifiers

PMID42515264
PMCPMC13416605

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.