Evidence map›Paper›PMID 42514753›Full record

ArticlePolymers2026

Multi-Factor Aging Mechanism and Multi-Parameter Synergistic Lifetime Prediction of HTV Silicone Rubber Composite Insulators.

Haocheng Liu, Bowen Wang, Zhiyao Fu, Kai Ning, Zhuan Jin, Haining Wang, Zhenglong Jiang

Abstract read
In one paragraph

Article in Polymers, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Haocheng LiuState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Co., Ltd., Changsha 410100, China.ORCID 0009-0004-8607-2933
Bowen WangState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Co., Ltd., Changsha 410100, China.ORCID 0000-0002-6264-4982
Zhiyao FuState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Co., Ltd., Changsha 410100, China.
Kai NingState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Co., Ltd., Changsha 410100, China.
Zhuan JinState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Co., Ltd., Changsha 410100, China.
Haining WangState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Co., Ltd., Changsha 410100, China.ORCID 0000-0003-1495-9696
Zhenglong JiangState Key Laboratory of Disaster Prevention & Reduction for Power Grid, Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Co., Ltd., Changsha 410100, China.

Funding

State Grid Hunan Electric Power Company Limited 5216AF250009
6 · The paper itself

Abstract

The long-term aging of HTV silicone rubber composite insulators under complex environments severely threatens power transmission line reliability. Traditional single/dual-parameter aging evaluation and lifetime prediction methods have low accuracy and poor generalization because they generally ignore multi-factor synergistic effects, pollution accumulation and electrical erosion. In this work, we systematically studied the aging characteristics of HTV silicone rubber under UV radiation, humidity, salt/ash contamination and their combined effects via accelerated aging tests and field sample verification, quantitatively analyzed the evolution of key mechanical, electrical and hydrophobic properties, and revealed the multi-factor synergistic aging mechanism from a micro-macro perspective with SEM, XPS and FTIR. The acceleration factor of the comprehensive accelerated-aging test was calculated as 43.8 through field-performance matching between 2000 h laboratory aging and 10-year field aging. We further established a "physical-pollution-electrical" three-dimensional evaluation system and constructed a multi-parameter synergistic lifetime prediction model through Pearson correlation analysis, VIF diagnosis and multiple stepwise regression. Compared with traditional dual-parameter models, the proposed model integrates physically interpretable degradation, contamination and electrical-stress indicators, thereby improving both prediction accuracy and engineering traceability. The model has 33% higher accuracy than traditional dual-parameter models, with average prediction errors of 0.55 years (same-manufacturer) and 1.0 years (cross-manufacturer). Five-fold cross-validation gives an MAE of 0.62 ± 0.08 years, and independent testing shows that most validation samples fall within the 95% prediction intervals, confirming favorable applicability within the present validation scope. These results provide theoretical and technical support for condition-based maintenance of composite insulators in power grids.

Indexed as

aging mechanismHTV silicone rubber composite insulatorlifetime predictionmulti-factor agingmulti-parameter synergy