ArticleMicromachines2026
Solid Concentration Measurement in Horizontal Gas-Solid Flows: An Adaptive Model Matching Strategy Using Array Capacitive Sensor.
Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
The accurate measurement of solid concentration in horizontal gas-solid flows is very important to guarantee production efficiency and process control. However, gravity causes uneven particle distribution, which creates a strong nonlinear relationship between sensor signals and solid concentration. When particle distribution changes, a single linear measurement model cannot provide enough detection accuracy. This paper proposes an adaptive model matching strategy for solid concentration measurement in horizontal gas-solid flows by using array capacitive sensor. The array capacitive sensor works with two excitation modes. The concave-ring excitation mode collects particle distribution information, and the multi-electrode excitation mode obtains solid concentration. These two types of signals build a dynamic matching relationship between particle distribution features and measurement models. In detail, signals from concave-ring excitation are input into the BP-Adaboost algorithm to classify particle distribution states. Multiple linear measurement models between multi-electrode signals and solid concentration are built through K-means clustering. After recognizing the particle distribution type, the Euclidean distance is used to automatically select the corresponding measurement model. A 3D simulation model combining gas-solid two-phase flow and electrostatic field is set up to test the feasibility of the proposed measurement method. Laboratory experiments are also conducted to prove its reliability. The test results show that the method can adapt well to various particle distribution states. Within the solid concentration range of 0.34-14.08%, the average relative measurement error is 4.41%. This method effectively improves the measurement accuracy of solid concentration in horizontal gas-solid two-phase flow.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.