ArticleMicromachines2026
The Signal-Integrity Control Strategy of a TSV Array for a Chiplet-Based System.
Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
In this research, a signal-integrity control strategy of a through-silicon via (TSV) array for a Chiplet-based system is developed, based on the backpropagation neural network (BP-NN) model and particle swarm optimization algorithm with linear decreasing inertia weight (PSO-LDIW). Based on the HFSS software, the simulation results of the TSV array are obtained. The irregular relationship between design parameters (TSV pitches, height of TSV, radius of TSV, thickness of oxide layer, and offset angle) and signal indexes (return loss, insertion loss, near-end, and far-end crosstalk) is established by the BP-NN model. Then, the design parameters of the TSV array are optimized by the PSO-LDIW algorithm to obtain the desired signal indexes. Based on the optimized design parameters, the effectiveness of the developed signal-integrity control strategy is verified by HFSS simulations. For the three verification cases, the relative errors between the BP-NN-predicted values and the corresponding HFSS simulation values range from 0.31% to 5.02%. The relative deviations of the HFSS results from the desired NEXT, FEXT, and return-loss targets are no greater than 5.72%, while the maximum absolute deviation from the desired insertion-loss target is 0.0160 dB. These results demonstrate the feasibility of the developed strategy for controlling the signal indexes of the TSV array in the tested cases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.